Linac-integrated kV-cone beam CT: Technical features and first applications

  • Uwe Oelfke, Ph.D.

      Affiliations

    • Department of Medical Physics in Radiation Therapy, DKFZ Heidelberg, Heidelberg, Germany
    • Corresponding Author InformationReprint requests to: U. Oelfke, Ph.D., Department of Medical Physics in Radiation Therapy, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
  • ,
  • Thomas Tücking, M.Sc.

      Affiliations

    • Department of Medical Physics in Radiation Therapy, DKFZ Heidelberg, Heidelberg, Germany
  • ,
  • Simeon Nill, Ph.D.

      Affiliations

    • Department of Medical Physics in Radiation Therapy, DKFZ Heidelberg, Heidelberg, Germany
  • ,
  • Annete Seeber, M.Sc.

      Affiliations

    • Department of Medical Physics in Radiation Therapy, DKFZ Heidelberg, Heidelberg, Germany
  • ,
  • Bernd Hesse, Ph.D.

      Affiliations

    • Department of Medical Physics in Radiation Therapy, DKFZ Heidelberg, Heidelberg, Germany
  • ,
  • Peter Huber, Ph.D., M.D.

      Affiliations

    • Department of Radiooncology, DKFZ Heidelberg, Heidelberg, Germany
  • ,
  • Christoph Thilmann, M.D.

      Affiliations

    • Department of Medical Physics in Radiation Therapy, DKFZ Heidelberg, Heidelberg, Germany

Received 21 December 2005

Abstract— 

One of the most prominent imaging techniques in image-guided radiotherapy (IGRT) is the acquisition of cone beam computed tomographies (CBCTs) at the linac with the patient in treatment position. CBCTs provide accurate 3-dimensional (3D) knowledge about the patient’s anatomy for every treatment fraction and are therefore well suited for all adaptive corrections of errors related to interfractional uncertainties of the treatment process. In this paper, we first describe the technical development and implementation of this new imaging technique at our linac, i.e., the hardware components and their operating parameters are discussed in detail for a standard image acquisition of CBCTs. Then, an extension of this approach for the acquisition of complete images for extended field of views—the “shifted detector” technique—is presented followed by a first investigation of how CBCTs can be reliably used for adaptive dose calculations. Finally, a first clinical application, the process of automatic patient positioning based on CBCT images, is discussed. From our investigations, we conclude that the technical development of linac-integrated CBCTs bears an enormous potential for the correction of interfractional treatment errors. However, image quality and reconstruction speed of the images leave room for improvement. The development of clinical strategies for the optimal application of this new image modality in a clinical environment is one the major tasks for the future.

Key Words:  IGRT , Cone beam CT , Adaptive radiotherapy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0958-3947(05)00195-0

doi:10.1016/j.meddos.2005.12.008

Medical Dosimetry
Volume 31, Issue 1 , Pages 62-70, Spring 2006