Medical Dosimetry
Volume 31, Issue 1 , Pages 51-61 , Spring 2006

Megavoltage cone-beam CT: System description and clinical applications

  • Olivier Morin, B.S.E.

      Affiliations

    • University of California San Francisco Comprehensive Cancer Center, Department of Radiation Oncology, San Francisco, CA
    • University of California San Francisco/University of California Berkeley Joint Graduate Group in Bioengineering, San Francisco, CA
  • ,
  • Amy Gillis, M.D.

      Affiliations

    • University of California San Francisco Comprehensive Cancer Center, Department of Radiation Oncology, San Francisco, CA
  • ,
  • Josephine Chen, Ph.D.

      Affiliations

    • University of California San Francisco Comprehensive Cancer Center, Department of Radiation Oncology, San Francisco, CA
  • ,
  • Michèle Aubin, M.S.E.E.

      Affiliations

    • University of California San Francisco Comprehensive Cancer Center, Department of Radiation Oncology, San Francisco, CA
  • ,
  • M. Kara Bucci, M.D.

      Affiliations

    • University of California San Francisco Comprehensive Cancer Center, Department of Radiation Oncology, San Francisco, CA
  • ,
  • Mack Roach III, M.D.

      Affiliations

    • University of California San Francisco Comprehensive Cancer Center, Department of Radiation Oncology, San Francisco, CA
  • ,
  • Jean Pouliot, Ph.D.

      Affiliations

    • University of California San Francisco Comprehensive Cancer Center, Department of Radiation Oncology, San Francisco, CA
    • University of California San Francisco/University of California Berkeley Joint Graduate Group in Bioengineering, San Francisco, CA
    • Corresponding Author InformationReprint requests to: Jean Pouliot, UCSF Comprehensive Cancer Center, Department of Radiation Oncology, 1600 Divisadero Street, Suite H1031, San Francisco, CA 94143

,Accepted 21 December 2005.

References 

  1. Jacob R , Hanlon A , Horwitz E , et al.   The relationship of increasing radiotherapy dose to reduced distant metastases and mortality in men with prostate cancer . Cancer . 2004;100:538–543
  2. Lee N , Xia P , Fischbein NJ , et al.   Intensity-modulated radiation therapy for head-and-neck cancer (The UCSF experience focusing on target volume delineation) . Int. J. Radiat. Oncol. Biol. Phys. . 2003;57:49–60
  3. Kuban D , Pollack A , Huang E , et al.   Hazards of dose escalation in prostate cancer radiotherapy . Int. J. Radiat. Oncol. Biol. Phys. . 2003;57:1260–1268
  4. Hurkmans CW , Cho BCJ , Damen E , et al.   Reduction of cardiac and lung complication probabilities after breast irradiation using conformal radiotherapy with or without intensity modulation . Radiother. Oncol. . 2002;62:163–171
  5. Tubiana M , Eschwege F . Conformal radiotherapy and intensity-modulated radiotherapy (Clinical data) . Acta Oncol. . 2000;39:555–567
  6. Shih HA , Jiang SB , Aljarrah KM , et al.   Internal target volume determined with expansion margins beyond composite gross tumor volume in three-dimensional conformal radiotherapy for lung cancer . Int. J. Radiat. Oncol. Biol. Phys. . 2004;60:613–622
  7. Lometti MW , Morin O , Aubin M , et al.   Intra- fractional and inter/intra-field organ motion and a proposal for a new patient set-up protocol. American Association of Physicists in Medicine 47th Annual Meeting, Seattle, WA . Med. Phys. . 2005;32:2160
  8. de Crevoisier R , Tucker SL , Dong L , et al.   Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy . Int. J. Radiat. Oncol. Biol. Phys. . 2005;62:965
  9. Hansen EK , Xia P , Quivey J , et al.   The roles of repeat CT imaging and re-planning during the course of IMRT for patients with head and neck cancer . Int. J. Radiat. Oncol. Biol. Phys. . 2004;60:S159
  10. Barker JL , Garden AS , Ang KK , et al.   Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head- and-neck cancer using an integrated CT/linear accelerator system . Int. J. Radiat. Oncol. Biol. Phys. . 2004;59:960–970
  11. Ma C-M , Paskalev K , et al.   In-room CT techniques for image-guided radiation therapy . Med. Dosim. . 2006;31:30–39
  12. Wong JR , Cheng CW , Grimm L , et al.   Clinical implementation of the world’s first Primatom, a combination of CT scanner and linear accelerator, for precise tumor targeting and treatment . Med. Phys. . 2001;17:271–276
  13. Jaffray DA , Siewerdsen JH , Wong JW , et al.   Flat-panel cone-beam computed tomography for image-guided radiation therapy . Int. J. Radiat. Oncol. Biol. Phys. . 2002;53:1337–1349
  14. Oelfke U , Tucking T, Nill S , et al.   Linac-integrated KV cone-beam CT (Technical features and first applications) . Med. Dosim. . 2006;31:62–70
  15. Sorensen SP , Chow E, Kriminski S , et al.   Image guided radiotherapy using a mobile kilovoltage x-ray device . Med. Dosim. . 2006;31:40–50
  16. Sillanpaa J , Chang J , Mageras G , et al.   Developments in megavoltage cone beam CT with an amorphous silicon EPID (Reduction of exposure and synchronization with respiratory gating) . Med. Phys. . 2005;32:819–829
  17. Pouliot J , Bani-Hashemi A , Chen J , et al.   Low-dose megavoltage cone-beam CT for radiation therapy . Int. J. Radiat. Oncol. Biol. Phys. . 2005;61:552–560
  18. Gildersleve J , Dearnaley DP , Evans PM , et al.   A randomised trial of patient repositioning during radiotherapy using a megavoltage imaging system . Radiother. Oncol. . 1994;31:161–168
  19. Evans PM , Gildersleve JQ , Rawlings C , et al.   Technical note (The implementation of patient position correction using a megavoltage imaging device on a linear accelerator) . Br. J. Radiol. . 1993;66:833–838
  20. Mackie TR , Kapatoes J , Ruchala K , et al.   Image guidance for precise conformal radiotherapy . Int. J. Radiat. Oncol. Biol. Phys. . 2003;56:89–105
  21. Swindell W , Simpson RG , Oleson JR , et al.   Computed tomography with a linear accelerator with radiotherapy applications . Med. Phys. . 1983;10:416–420
  22. Nakagawa K , Akanuma A , Aoki Y , et al.   A quantitative patient set-up and verification system using megavoltage CT scanning . Int. J. Radiat. Oncol. Biol. Phys. . 1991;21:228
  23. Ruchala KJ , Olivera GH , Schloesser EA , et al.   Megavoltage CT on a tomotherapy system . Phys. Med. Biol. . 1999;44:2597–2621
  24. Mosleh-Shirazi MA , Evans PM , Swindell W , et al.   A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy . Radiother. Oncol. . 1998;48:319–328
  25. Midgley S , Millar RM , Dudson J . A feasibility study for megavoltage cone beam CT using a commercial EPID . Phys. Med. Biol. . 1998;43:155–169
  26. Spies L , Ebert M , Groh BA , et al.   Correction of scatter in megavoltage cone-beam CT . Phys. Med. Biol. . 2001;46:821–833
  27. Ford EC , Chang J , Mueller K , et al.   Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device (Potential for verification of radiotherapy of lung cancer) . Med. Phys. . 2002;29:2913–2924
  28. Groh BA , Siewerdsen JH , Drake DG , et al.   A performance comparison of flat-panel imager-based MV and kV cone-beam CT . Med. Phys. . 2002;29:967–975
  29. Seppi EJ , Munro P , Johnsen SW , et al.   Megavoltage cone-beam computed tomography using a high-efficiency image receptor . Int. J. Radiat. Oncol. Biol. Phys. . 2003;55:793–803
  30. Ghelmansarai F , Bani-Hashemi A , Pouliot J , et al.   In: Soft tissue visualization using a highly efficient megavoltage cone beam CT imaging system. Proceedings of the International Society for Optical Engineering Meeting, San Diego, 2003 . San Diego: Medical Imaging; 2005;p. 159–170 5745:
  31. Sidhu K , Ford EC , Spirou S , et al.   Optimization of conformal thoracic radiotherapy using cone-beam CT imaging for treatment verification . Int. J. Radiat. Oncol. Biol. Phys. . 2003;55:757–767
  32. Anastasio MA , Daxin S , Xiaochuan P , et al.   A preliminary investigation of local tomography for megavoltage CT imaging . Med. Phys. . 2003;30:2969–2980
  33. Ghelmansarai FA , Misra S , Pouliot J . In: Electronic readout of a-Si EPIDs for optimum signal-to-noise ratio. Proceedings of the International Society for Optical Engineering Meeting, San Diego, 2003. . San Diego: Medical Imaging; 2003;p. 788–798 5030:
  34. Pouliot J , Bani-Hashemi A , Aubin M , et al.   Clinical integration of a MV cone-beam system for image-guided treatment. American Association of Physicists in Medicine 47th Annual Meeting, Seattle, WA . Med. Phys. . 2005;32:1938
  35. Siewerdsen JH , Jaffray DA . Cone-beam computed tomography with a flat-panel imager (Magnitude and effects of x-ray scatter) . Med. Phys. . 2001;28:220–231
  36. Siewerdsen JH , Moseley DJ , Bakhtiar B , et al.   The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors . Med. Phys. . 2004;31:3506–3520
  37. Jaffray DA , Battista JJ , Fenster A , et al.   X-ray scatter in megavoltage transmission radiography (Physical characteristics and influence on image quality) . Med. Phys. . 1994;21:45–60
  38. Morin O , Chen J , Aubin M , et al.   In: Evaluation of the mechanical stability of megavoltage imaging system using a new flat panel positioner. Proceedings of the International Society for Optical Engineering Meeting, San Diego, 2005 . San Diego: Medical Imaging; 2005;p. 704–710 5745:
  39. Wiesent K , Barth K , Navab N , et al.   Enhanced 3D-reconstruction algorithm for C-arm systems suitable for interventional procedures . IEEE Trans. Med. Imaging . 2000;19:391–403
  40. Morin O , Bose S , Chen J , et al.   The impact of portal imager shifts and the assumption of rigid isocentricity on megavoltage cone-beam CT images. American Association of Physicists in Medicine 47th Annual Meeting, Seattle, WA . Med. Phys. . 2005;32:1916
  41. Downs TM , Roach M , Grossfeld GD , et al.   The University of California, San Francisco (UCSF) experience with permanently implanted gold markers for daily prostate realignment during radiation therapy . Int. J. Radiat. Oncol. Biol. Phys. . 2002;54:280
  42. Morin O , Chen J , Aubin M , et al.   Dose calculation using megavoltage cone-beam CT . American Society for Therapeutic Radiology and Oncology 47th Annual Meeting, Denver, CO. Int. J. Radiat. Oncol. Biol. Phys. . 2005;63:S62–S63
  43. Low DA , Harms WB , Mutic S , et al.   A technique for the quantitative evaluation of dose distributions . Med. Phys. . 1998;25:656–661
  44. Mahnken AH , Raupach R , Wildberger JE , et al.   A new algorithm for metal artifact reduction in computed tomography (In vitro and in vivo evaluation after total hip replacement) . Invest. Radiol. . 2003;38:769–775
  45. Aubin M , Morin O , Bucci K , et al.   Effectiveness of MV CBCT for patients with implanted high-Z material. American Association of Physicists in Medicine 47th Annual Meeting, Seattle, WA . Med. Phys. . 2005;32:1933
  46. Nishimura K , Svatos M , Zheng Z , et al.   Target flattener combinations for combined therapy and high contrast megavoltage imaging. American Association of Physicists in Medicine 47th Annual Meeting, Seattle, WA . Med. Phys. . 2005;32:1909
  47. Flampouri S , Evans PM , Verhaegen F , et al.   Optimization of accelerator target and detector for portal imaging using Monte Carlo simulation and experiment . Phys. Med. Biol. . 2002;47:3331–3349
  48. Zheng Z , Ghelmansarai F , Svatos M . Simplified beamlines for high performance portal imaging. American Association of Physicists in Medicine 46th Annual Meeting, Pittsburgh, PA . Med. Phys. . 2003;30:1474
  49. Chen J , Chuang CF , Morin O , Aubin M , Pouliot J . Calibration of an amorphous-silicon flat panel portal imager for exit-beam dosimetry . Med. Phys. . 2006;33:584–594
  50. Partridge M , Ebert M , Hesse BM . IMRT verification by three-dimensional dose reconstruction from portal beam measurements . Med. Phys. . 2002;29:1847–1858
  51. Pouliot J , Chen J , Zheng Z , et al.   Dose reconstruction from MV conebeam CT for dose-guided radiation therapy. American Association of Physicists in Medicine 46th Annual Meeting, Pittsburgh, PA . Med. Phys. . 2004;31:1832

PII: S0958-3947(05)00196-2

doi: 10.1016/j.meddos.2005.12.009

Medical Dosimetry
Volume 31, Issue 1 , Pages 51-61 , Spring 2006