Medical Dosimetry
Volume 31, Issue 1 , Pages 20-29 , Spring 2006

Ultrasound-based guidance of intensity-modulated radiation therapy

,Accepted 21 December 2005.

References 

  1. Curie P , Curie J . Développement par pression de lélectricite polaire dans les cristaux hémièdres á faces inclinées . C. R. Acad. Sci. (Paris) . 1880;91:294
  2. Nickolls, Peter. Biomedical Engineering Class Notes. Professor, University of Sydney, Australia.
  3. Fung AY , Enke CA , Ayyangar KM , et al.   Prostate motion and isocenter adjustment from ultrasound-based localization during delivery of radiation therapy . Int. J. Radiat. Oncol. Biol. Phys. . 2005;61:984–992
  4. Trichter F , Ennis RD . Prostate localization using transabdominal ultrasound imaging . Int. J. Radiat. Oncol. Biol. Phys. . 2003;56:1225–1233
  5. Meeks SL , Buatti JM , Bouchet LG , et al.   Ultrasound-guided extracranial radiosurgery (Technique and application) . Int. J. Radiat. Oncol. Biol. Phys. . 2003;55:1092–1101
  6. Tome WA , Meeks SL , Orton NP , et al.   Commissioning and quality assurance of an optically guided three-dimensional ultrasound target localization system for radiotherapy . Med. Phys. . 2002;29:1781–1788
  7. Bouchet LG , Meeks SL , Goodchild G , et al.   Calibration of three-dimensional ultrasound images for image-guided radiation therapy . Phys. Med. Biol. . 2001;46:559–577
  8. Vac-Lock, MED-TEC. Inc., Orange City, IA.
  9. Goodsitt MM , Carson PL , Witt S , et al.   Real-time B-mode ultrasound quality control test procedures. Report of AAPM Ultrasound Task Group No. 1 . Med. Phys. . 1998;25:1385–1406
  10. Chen Q , Zagzebski JA . Simulation study of effects of speed of sound and attenuation on ultrasound lateral resolution . Ultrasound Med. Biol. . 2004;30:1297–1306
  11. McGahan JP , Ryu J , Fogata M . Ultrasound probe pressure as a source of error in prostate localization for external beam radiotherapy . Int. J. Radiat. Oncol. Biol. Phys. . 2004;60:788–793
  12. Serago CF , Chungbin SJ , Buskirk SJ , et al.   Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy . Int. J. Radiat. Oncol. Biol. Phys. . 2002;53:1130–1138
  13. Artignan X , Smitsmans MH , Lebesque JV , et al.   Online ultrasound image guidance for radiotherapy of prostate cancer (Impact of image acquisition on prostate displacement) . Int. J. Radiat. Oncol. Biol. Phys. . 2004;59:595–601
  14. Treece GM , Gee AH , Prager RW . RF and amplitude-based probe pressure correction for 3D ultrasound . Ultrasound Med. Biol. . 2005;31:493–503
  15. Chandra A , Dong L , Huang E , et al.   Experience of ultrasound-based daily prostate localization . Int. J. Radiat. Oncol. Biol. Phys. . 2003;56:436–447
  16. Badiozamani KR , Wallner K , Cavanagh W , et al.   Comparability of CT-based and TRUS-based prostate volumes . Int. J. Radiat. Oncol. Biol. Phys. . 1999;43:375–378
  17. Hoffelt SC , Marshall LM , Garzotto M , et al.   A comparison of CT scan to transrectal ultrasound-measured prostate volume in untreated prostate cancer . Int. J. Radiat. Oncol. Biol. Phys. . 2003;57:29–32
  18. Helmick R , Tarver R , Chan R , et al.   Evaluation of post-plan dosimetry using TRUS and CT after transperineal prostate seed implant . Med. Dosim. . 2002;27:289–293
  19. Chinnaiyan P , Tomee W , Patel R , et al.   3D-ultrasound guided radiation therapy in the post-prostatectomy setting . Technol. Cancer Res. Treat. . 2003;2:455–458
  20. Britton KR , Takai Y , Mitsuya M , et al.   Evaluation of inter- and intrafraction organ motion during intensity modulated radiation therapy (IMRT) for localized prostate cancer measured by a newly developed on-board image-guided system . Radiat. Med. . 2005;23:14–24
  21. Madsen BL , His RA , Pham HT , et al.   Intrafractional stability of the prostate using a stereotactic radiotherapy technique . Int. J. Radiat. Oncol. Biol. Phys. . 2003;57:1285–1291
  22. Huang E , Dong L , Chandra A , et al.   Intrafraction prostate motion during IMRT for prostate cancer . Int. J. Radiat. Oncol. Biol. Phys. . 2002;53:261–268
  23. Mah D , Freedman G , Milestone B , et al.   Measurement of intrafractional prostate motion using magnetic resonance imaging . Int. J. Radiat. Oncol. Biol. Phys. . 2002;54:568–575
  24. Jani AB , Gratzle J , Muresan E , et al.   Analysis of acute toxicity with use of transabdominal ultrasonography for prostate positioning during intensity-modulated radiotherapy . Urology . 2005;65:504–508
  25. Jani AB , Gratzle J , Muresan E , et al.   Impact on late toxicity of using transabdominal ultrasound for prostate cancer patients treated with intensity modulated radiotherapy . Technol. Cancer Res. Treat. . 2005;4:115–120
  26. Little DJ , Dong L , Levy LB , et al.   Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT (Implications for treatment margins) . Int. J. Radiat. Oncol. Biol. Phys. . 2003;56:1218–1224
  27. Langen KM , Pouliot J , Anezinos C , et al.   Evaluation of ultrasound-based prostate localization for image-guided radiotherapy . Int. J. Radiat. Oncol. Biol. Phys. . 2003;57:635–644
  28. Van den Heuvel F , Powell T , Seppi E , et al.   Independent verification of ultrasound based image-guided radiation treatment, using electronic portal imaging and implanted gold markers . Med. Phys. . 2003;30:2878–2887
  29. Hsu A , Miller NR , Evans PM , et al.   Feasibility of using ultrasound for real-time tracking during radiotherapy . Med. Phys. . 2005;32:1500–1512

PII: S0958-3947(05)00201-3

doi: 10.1016/j.meddos.2005.12.011

Medical Dosimetry