Medical Dosimetry
Volume 31, Issue 1 , Pages 12-19 , Spring 2006

A multi-platform approach to image guided radiation therapy (IGRT)

  • Christopher Amies, Ph.D.

      Affiliations

    • Clinical and Collaborative Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
    • Corresponding Author InformationReprint requests to: Christopher Amies, Ph.D., 4040 Nelson Avenue, Concord, CA 94520
  • ,
  • Ali Bani-Hashemi, Ph.D.

      Affiliations

    • Advance Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
  • ,
  • Juan-Carlos Celi, Ph.D.

      Affiliations

    • Product Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
  • ,
  • Guillaume Grousset, M.Sc.

      Affiliations

    • Clinical and Collaborative Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
  • ,
  • Farhad Ghelmansarai, Ph.D.

      Affiliations

    • Advance Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
  • ,
  • Dimitre Hristov, Ph.D.

      Affiliations

    • Clinical and Collaborative Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
  • ,
  • Derek Lane, M.Sc.

      Affiliations

    • Product Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
  • ,
  • Matthias Mitschke, Ph.D.

      Affiliations

    • Product Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
  • ,
  • Ajit Singh, Ph.D.

      Affiliations

    • Clinical and Collaborative Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
  • ,
  • Himanshu Shukla, Ph.D.

      Affiliations

    • Clinical and Collaborative Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
  • ,
  • Joerg Stein, Ph.D.

      Affiliations

    • Clinical and Collaborative Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA
  • ,
  • Mark Wofford

      Affiliations

    • Clinical and Collaborative Development, Siemens Medical Solutions, Oncology Care Systems Group, Concord, CA

,Accepted 21 December 2005.

References 

  1. Vargas C , Martinez A , Kestin LL , et al.   Dose-volume analysis of predictors for chronic rectal toxicity after treatment of prostate cancer with adaptive image-guided radiotherapy . Int J Radiat Oncol Biol Phys . 2005;62:1297–1308
  2. Wong JR , Grimm L , Uematsu M , et al.   Image-guided radiotherapy for prostate cancer by CT-linear accelerator combination (Prostate movements and dosimetric considerations) . Int J Radiat Oncol Biol Phys . 2005;61:561–569
  3. de Crevoisier R , Tucker SL , Dong L , et al.   Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy . Int J Radiat Oncol Biol Phys . 2005;62:965–973
  4. Schaly B , Bauman GS , Song W , et al.   Dosimetric impact of image-guided 3D conformal radiation therapy of prostate cancer . Phys Med Biol . 2005;50:3083–3101
  5. Hermosillo G , Chefd’Hotel C , Faugeras OD . Variational methods for multimodal image matching . Int J Comput Vis . 2002;50:329–343
  6. Rousson M.; Khamene A.; Diallo M.; et al. Constrained Surface Evolutions for Prostate and Bladder Segmentation in CT Images. Proceedings of the ICCV 2005, Computer Vision for Biomedical Image Applications Workshop, Beijing, China; 2005.
  7. Uematsu M , Fukui T , Shioda A . A dual computed tomography linear accelerator unit for stereotactic radiotherapy (A new approach without cranial fixated stereotactic frames) . Int. J. Radiat. Oncol. Biol. Phys . 1996;35:587–592
  8. Hoogeman MS , van Herk M , de Bois J , et al.   Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer . Radiother. Oncol . 2005;74:177–185
  9. Mohan R , Zhang X , Wang H , et al.   Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes . Int J Radiat Oncol Biol Phys . 2005;61:1258–1266
  10. Court LE , Dong L , Lee AK , et al.   An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer . Int J Radiat Oncol Biol Phys . 2005;62:154–163
  11. Ma C , Paskalev L . In-room CT techniques for image-guided radiation therapy . Med Dosim . 2006;31:30–39
  12. Pouliot J , Bani-Hasemi A , Chen J , et al.   Low-dose megavoltage cone-beam CT for radiation therapy . Int J Radiat Oncol Biol Phys . 2005;61:552–560
  13. Feldkamp LA , Davis LC , Kress JW . Practical conebeam algorithm . J Opt Soc Am A . 1984;1:612–619
  14. Morin O.; Gillis A.; Chen J., et al. Megavotage cone-beam CT: System description and IGRT clinical applications. Med Dosim In press.
  15. Ghelmansarai F . Soft tissue visualization using a highly efficient megavoltage cone beam CT imaging system. 45th Annual AAPM Meeting . Med Phys . 2005;32:2131
  16. Flampouri S , McNair HA , Donovan EM , et al.   Initial patient imaging with an optimised radiotherapy beam for portal imaging . Radiother Oncol . 2005;76:63–71
  17. Antonuk L . Electronic portal imaging devices (A review and historical perspective of contemporary technologies and research) . Phys Med Biol . 2002;47:R31–R65
  18. Pang G , Rowlands JA . Development of high quantum efficiency, flat panel thick detectors for megavoltage X-ray imaging (A novel direct-conversion design and its feasibility) . Med Phys . 2004;31:3004–3016
  19. Navab N , Bani-Hashemi A , Nadar MS , et al.   3D Reconstruction from projection matrices in a C-arm based 3D-angiography system . MICCAI . 1998;119–129
  20. Siewerdsen JH , Mosely DJ , Burch S , et al.   Volume CT with a flat panel detector on a mobile, isocentric C-arm (Pre-clinical investigation of minimally invasive surgery) . Med Phys . 2005;32:241–254
  21. Jaffray DA , Siewerdsen JH , Wong JW , et al.   Flat panel cone beam computed tomography for image based radiation therapy . Int J Radiat Oncol Biol Phys . 2002;53:1337–1349
  22. Sorensen SP , Chow E , Kriminski S , et al.   Image guided radiotherapy using a mobile kilovoltage x-ray device . Med Dosim . 2006;31:40–50
  23. Ozhasoglu C , Murphy MJ . Issues in respiratory motion compensation during external-beam radiotherapy . Int J Radiat Oncol Biol Phys . 2002;52:1389–1399
  24. Fowler JF , Ritter MA , Chappell RJ , et al.   What hypofractionated protocols should be tested for prostate cancer? . Int J Radiat Oncol Biol Phys . 2003;56:1093–1104
  25. Timmerman RD , Kavanagh BD . Stereotactic body radiation therapy . Curr Probl Cancer . 2005;29:120–157
  26. Nill S , Unkelbach J , Dietrich L , et al.   Online correction for respiratory motion (Evaluation of two different imaging geometries) . Phys Med Biol . 2005;50:4087–4096

 Disclaimer: The information about concept products described in this paper is preliminary and is subject to change. Any potential product described herein may be under development and is not presently available for commercial distribution in the U.S., and future availability cannot be ensured.

PII: S0958-3947(05)00202-5

doi: 10.1016/j.meddos.2005.12.013

Medical Dosimetry
Volume 31, Issue 1 , Pages 12-19 , Spring 2006