Medical Dosimetry
Volume 31, Issue 3 , Pages 197-200, Autumn 2006

Evaluation of bladder dose in intensity-modulated radiation therapy of the prostate

  • P.D. Higgins, Ph.D.

      Affiliations

    • Corresponding Author InformationReprint requests to: Dr. Patrick Higgins, University of Minnesota, Department of Therapeutic Radiology—Radiation Oncology, Minneapolis, MN 55455.
  • ,
  • R. Weaver, C.M.D.
  • ,
  • K.E. Dusenbery, M.D.

University of Minnesota Medical School, Department of Therapeutic Radiology—Radiation Oncology, Minneapolis, MN

Received 7 June 2005; accepted 16 December 2005.

Abstract 

Day-to-day variation in bladder and rectal filling affects prostate location and positioning accuracy. Systems using ultrasonic localization or gold seed placement are most often used to help correct for these changes. At some institutions, patients are instructed to empty their rectum and fill their bladders prior to treatment in an attempt to standardize the prostate location, displace small bowel out of the radiation field, and move some of the bladder wall away from the high-dose area. Although instructed to come to treatment with a full bladder, it is presumed that there is variability in bladder filling each day of treatment, depending on the amount of fluids consumed and time to treatment. We have reviewed daily bladder volumes on a subset of 5 prostate patients, all of them prescribed to receive 7560 cGy in 42 fractions, and have evaluated the dosimetric consequences of bladder volume changes from full to two-third or one-third filling. All of these patients’ positions were verified daily with ultrasonic localization. Those measurements have been used to help analyze the actual treated bladder volumes for comparison with the treatment plan. We find that, in general, maximum filling only occurred on the initial simulation/image acquisition day and was typically smaller on all the following treatment days. Based on our dose-volume model, we estimate that average bladder daily doses were 8–50% higher than predicted by the initial intensity-modulation radiation therapy (IMRT) plan.

Key Words:  IMRT , Bladder volume , Prostate cancer , Dosimetry

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0958-3947(06)00044-6

doi:10.1016/j.meddos.2005.12.016

Medical Dosimetry
Volume 31, Issue 3 , Pages 197-200, Autumn 2006