Medical Dosimetry
Volume 32, Issue 1 , Pages 1-6, Spring 2007

The effect of positional realignment on dose delivery to the prostate and organs-at-risk for 3DCRT

Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY

Received 9 December 2005; accepted 8 August 2006.

Abstract 

In this study, we evaluate the impact of daily image-guided patient repositioning on dose delivery to prostate and sensitive organs in the treatment of prostate carcinoma with 3-dimensional conformal radiation therapy (3DCRT). Five patients with substantial ultrasound-documented interfractional prostate motion during their 3DCRT treatment course were selected. Starting with the original treatment plan, 2 additional plans were retrospectively generated for each patient. In one set, organ contours were moved for each fraction, thus simulating positioning with misalignment caused by organ motion if ultrasound guidance were not used. In a second set of plans, the isocenter was shifted, as were the organ contours, simulating realignment based on the ultrasound image. In all cases, the number of planned monitor units was set to those of the original plan. For a given patient, isodose distributions, dose-volume histograms (DVHs), equivalent uniform dose (EUD) for prostate, and generalized equivalent uniform dose (gEUDs) for bladder and rectum were calculated for each fraction and then combined for each shift condition. In all reconstructed plans, the results show no substantial changes in dose coverage of the prostate (< 0.21% change in EUD) compared to the original plan. However, in some cases with no realignment, a larger volume of the bladder or rectum gets higher dose, with the consequent gEUD for each organ significantly greater compared to the original plan.

Key Words: Prostate carcinoma, Organ motion, Ultrasound guidance, 3D conformal radiotherapy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0958-3947(06)00125-7

doi:10.1016/j.meddos.2006.08.002

Medical Dosimetry
Volume 32, Issue 1 , Pages 1-6, Spring 2007