Medical Dosimetry
Volume 32, Issue 3 , Pages 166-171, Autumn 2007

Helical Tomotherapy for Radiotherapy in Esophageal Cancer: A Preferred Plan With Better Conformal Target Coverage and More Homogeneous Dose Distribution

  • Yi-Jen Chen, M.D., Ph.D.

      Affiliations

    • Corresponding Author InformationReprint requests to: Yi-Jen Chen, M.D., Ph.D., Division of Radiation Oncology, City of Hope National Medical Center, 1500 East Duarte Road, Duarte, CA 91010-3000.
  • ,
  • An Liu, Ph.D.
  • ,
  • Chunhui Han, Ph.D.
  • ,
  • Peter T. Tsai, C.M.D.
  • ,
  • Timothy E. Schultheiss, Ph.D.
  • ,
  • Richard D. Pezner, M.D.
  • ,
  • Nilesh Vora, M.D.

      Affiliations

    • Internal Medicine, Harbor-UCLA Medical Center, Torrance, CA
  • ,
  • Dean Lim, M.D.

      Affiliations

    • Division of Radiation Oncology, Medical Oncology, City of Hope National Medical Center, Duarte, CA
  • ,
  • Stephen Shibata, M.D.

      Affiliations

    • Division of Radiation Oncology, Medical Oncology, City of Hope National Medical Center, Duarte, CA
  • ,
  • Kemp H. Kernstine, M.D., Ph.D.

      Affiliations

    • Division of Radiation Oncology Thoracic Surgery, City of Hope National Medical Center, Duarte, CA
  • ,
  • Jeffrey Y.C. Wong, M.D.

Received 9 December 2006; accepted 14 December 2006.

Abstract 

We compare different radiotherapy techniques—helical tomotherapy (tomotherapy), step-and-shoot IMRT (IMRT), and 3-dimensional conformal radiotherapy (3DCRT)—for patients with mid-distal esophageal carcinoma on the basis of dosimetric analysis. Six patients with locally advanced mid-distal esophageal carcinoma were treated with neoadjuvant chemoradiation followed by surgery. Radiotherapy included 50 Gy to gross planning target volume (PTV) and 45 Gy to elective PTV in 25 fractions. Tomotherapy, IMRT, and 3DCRT plans were generated. Dose-volume histograms (DVHs), homogeneity index (HI), volumes of lung receiving more than 10, 15, or 20 Gy (V10, V15, V20), and volumes of heart receiving more than 30 or 45 Gy (V30, V45) were determined. Statistical analysis was performed by paired t-tests. By isodose distributions and DVHs, tomotherapy plans showed sharper dose gradients, more conformal coverage, and better HI for both gross and elective PTVs compared with IMRT or 3DCRT plans. Mean V20 of lung was significantly reduced in tomotherapy plans. However, tomotherapy and IMRT plans resulted in larger V10 of lung compared to 3DCRT plans. The heart was significantly spared in tomotherapy and IMRT plans compared to 3DCRT plans in terms of V30 and V45. We conclude that tomotherapy plans are superior in terms of target conformity, dose homogeneity, and V20 of lung.

Key Words: Helical tomotherapy, IMRT, Esophageal cancer, Radiotherapy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0958-3947(06)00178-6

doi:10.1016/j.meddos.2006.12.003

Medical Dosimetry
Volume 32, Issue 3 , Pages 166-171, Autumn 2007