Performance Characteristics and Quality Assurance Aspects of Kilovoltage Cone-Beam CT on Medical Linear Accelerator

  • Cheng B. Saw, Ph.D.

      Affiliations

    • Department of Radiation Oncology, University of Pittsburgh Cancer Institute Pittsburgh, PA
    • Corresponding Author InformationReprint requests to: Cheng B. Saw, Ph.D., Medical Physics Division, Room 541, UPMC Cancer Pavilion, 5150 Centre Avenue, Pittsburgh, PA 15232.
  • ,
  • Yong Yang, Ph.D.

      Affiliations

    • Department of Radiation Oncology, University of Pittsburgh Cancer Institute Pittsburgh, PA
  • ,
  • Fang Li, M.S.

      Affiliations

    • Department of Radiation Oncology, University of Pittsburgh Cancer Institute Pittsburgh, PA
  • ,
  • Ning J. Yue, Ph.D.

      Affiliations

    • Department of Radiation Oncology, The Cancer Institute of New Jersey, UMDNJ-Robert Wood Johnson Medical School, New Brunswick, NJ
  • ,
  • ChuXiong Ding, Ph.D.

      Affiliations

    • Department of Radiation Oncology, University of Pittsburgh Cancer Institute Pittsburgh, PA
  • ,
  • Krishna Komanduri, Ph.D.

      Affiliations

    • Department of Radiation Oncology, University of Pittsburgh Cancer Institute Pittsburgh, PA
  • ,
  • Saiful Huq, Ph.D.

      Affiliations

    • Department of Radiation Oncology, University of Pittsburgh Cancer Institute Pittsburgh, PA
  • ,
  • Dwight E. Heron, M.D.

      Affiliations

    • Department of Radiation Oncology, University of Pittsburgh Cancer Institute Pittsburgh, PA

,Accepted 11 January 2007.

References 

  1. Purdy JA. Intensity-modulated radiation therapy. Int. J. Radiat. Oncol. Biol. Phys. 1996;35:845–846
  2. Intensity Modulated Radiation Therapy Collaborative Working Group. Intensity-modulated radiotherapy: Current status and issues of interest. Int. J. Radiat. Oncol. Biol. Phys. 2001;51:880–914
  3. Saw CB, Ayyangar KM, Enke CA. MIMiC-based IMRT–Part I. Med. Dosim. 2001;26:1
  4. Saw CB, Ayyangar KM, Enke CA. MLC-based IMRT–Part II. Med. Dosim. 2001;26:111–112
  5. Saw CB, Zhen W, Ayyangar KM, et al. Cliniical aspects of IMRT–Part III. Med. Dosim. 2002;27:75–77
  6. Ezzell GA, Galvin JM, Low D, et al. Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee. Med. Phys. 2003;30:2089–2115
  7. Brandner ED, Heron D, Wu A, et al. Localizing moving targets and organs using motion-managed CT. Med. Dosim. 2006;31:134–140
  8. Jiang SB. Technical aspects of image-guided respiration-gated radiation therapy. Med. Dosim. 2006;31:141–151
  9. Keall P, Vedam S, George R, et al. The clinical implementation of respiratory-gated intensity modulated radiotherapy. Med. Dosim. 2006;31:142–162
  10. Fung AYC, Ayyangar KM, Djajaputra D, et al. Ultrasound-based guidance of intensity-modulated radiation therapy. Med. Dosim. 2006;31:20–29
  11. Ma CM, Paskalev K. In-room CT technique for image-guided radiation therapy. Med. Dosim. 2006;31:30–39
  12. Sorensen S, Chow PE, Kriminski S, et al. Image-guided radiotherapy using a mobile kilovoltage x-ray device. Med. Dosim. 2006;31:40–50
  13. Morin O, Gillis A, Chen J, et al. Megavoltage cone-beam CT: System description and clinical applications. Med. Dosim. 2006;31:51–61
  14. Oelfke U, Tucking T, Nill S, et al. Linac-integrated kv-cone beam CT: Technical features and first applications. Med. Dosim. 2006;31:52–70
  15. Huntzinger C, Munro P, Johnson S, et al. Dynamic targeting image-guided radiotherapy. Med. Dosim. 2006;31:113–125
  16. Thorson T, Prosser T. X-ray volume imaging in image-guided radiotherapy. Med. Dosim. 2006;31:126–133
  17. Willoughby TR, Kupelian PA, Pouliot J, et al. Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2006;65:528–534
  18. Huntzinger C, Friedman W, Bova F, et al. Trilogy image-guided stereotactic radiosurgery. Med. Dosim. 2007;32:121–133
  19. Wagner TH, Meeks SL, Bova FJ, et al. Optical tracking technology in stereotactic radiation therapy. Med. Dosim. 2007;32:111–120
  20. Siewerdsen JH, Jaffray DA. Cone-beam computerized tomography with a flat panel imager: Magnitude and effects of x-ray scatter. Med. Phys. 2001;28:220–231
  21. Hammond R, Yoo S, Guan H. On-board imaging system: Implementation and quality assurance procedures. In: Medical Physics Monograph No. 32—Integrating New Technologies into the Clinic: Monte Carlo and Image-Guided Radiation Therapy. Madison, WI: Medical Physics Publishing; 2006;p. 653–668
  22. Islam MK, Purdie TG, Norrlinger BD, et al. Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy. Med. Phys. 2006;33:1573–1582
  23. Mutic S, Palta JR, Butker EK, et al. Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: Report of the AAPM Radiation Therapy Committee Task Group No. 66. Med. Phys. 2003;30:2762–2792
  24. Sharpe MB, Moseley DJ, Purdie TG, et al. The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator. Med. Phys. 2006;33:136–144

PII: S0958-3947(07)00005-2

doi: 10.1016/j.meddos.2007.01.003

Medical Dosimetry
Volume 32, Issue 2 , Pages 80-85 , Summer 2007