Volume 32, Issue 3 , Pages 211-215, Autumn 2007

Correlation Between Detector Array Measurements and a Computer Algorithm for Enhanced Dynamic Wedge Profiles

Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY

Received 18 January 2007; accepted 6 February 2007.

Abstract 

Verification of dosimetric data computed by a treatment planning system is necessary in the commissioning process for any clinical software, just as it is necessary for any annual quality assurance testing. Direct verification of the dosimetric data is achievable when calculating the enhanced dynamic wedge (EDW) off-axis ratio at each point of interest. As mathematical models for hand-calculating such factors are still evolving, measurement of these external beam arrangements has proven significantly more accurate. This research presents a correlation for measured and planned data, specific for 6- and 18-MV photon beams on a Varian 21EX linear accelerator, using the EDW mode. Field generation was created using the Varian Eclipse treatment planning system. On treatment field delivery, the Sun Nuclear MapCHECK diode array was used to plot each beam profile in 2 dimensions. Wedge angles of 10°, 15°, 20°, 25°, 30°, 45° and 60° were studied here, under isocentric geometry, at a fixed water equivalent depth of 15 cm. Field size dependence was considered with each wedge and energy combination, where symmetric apertures of 5 × 5 cm2, 10 × 10 cm2, 15 × 15 cm2 and 20 × 20 cm2 were used. Accurate dosimetric results were found to be achievable when using this treatment planning system to within 2.8% maximum deviation, and to within 1% deviation averaged over all. The diode array also proved to be simple and ideally suited for EDW measurements.

Key Words: Diode, Eclipse, EDW, MapCHECK

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0958-3947(07)00044-1

doi:10.1016/j.meddos.2007.02.001

Medical Dosimetry
Volume 32, Issue 3 , Pages 211-215, Autumn 2007