Quantification of Dosimetric Impact of Implementation of On-Board Imaging (OBI) for IMRT Treatment of Head-And-Neck Malignancies

This data was presented, in part, at the 88th Annual Meeting of the American Radium Society, Maui, 2006.

Department of Radiation Oncology, Emory University, Atlanta, GA

Received 18 July 2006; accepted 20 February 2007.

Abstract 

Implementation of daily kilovoltage imaging for setup verification improves the reproducibility of treatment by eliminating small random setup errors. We evaluate the dosimetric consequences of such shifts, not yet evaluated, in a group of head-and-neck cancer patients (ENT) treated with intensity modulated radiation therapy (IMRT) at Emory University. Twelve patients with ENT malignancies were analyzed. On-Board Imaging (OBI) was used in at least 70% of each patient’s treatment sessions. An isodose distribution was generated for each fraction, with the isocenter shifted to its calculated location prior to OBI repositioning. These plans were summed and then compared to the simulation plan for coverage of target structures. For these 12 patients, there were a total of 18 planning target volumes (PTV). The mean (range) percent reduction in minimum dose was 12.1% (−1.0 to 43.3). For 10 right necks and 9 left necks treated, the mean percent reduction in minimum dose was 11.8% (−0.6 to 39.7) and 13.3% (−3.6 to 31.2), respectively. The mean reduction in mean dose to the PTV was 1.3% (0 to 5.1). The mean reduction in mean dose to the right and left necks was 1.0% (0.2 to 3.9) and 1.13% (0.4 to 3.4), respectively. From this analysis, we conclude that the shifts made were small and random, with essentially no change in mean dose delivered to target structures. There is, however, significant improvement in the minimum dose delivered. Underdosing even a small portion of the tumor potentially sacrifices the probability of local control; correcting these setup errors seems desirable.

Key Words: On-Board Imaging (OBI), Interfraction motion management, Head-and-neck malignancies, Image-guided radiation therapy (IGRT)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0958-3947(07)00052-0

doi:10.1016/j.meddos.2007.02.008

Medical Dosimetry
Volume 32, Issue 4 , Pages 287-294, Winter 2007