« Previous
Next »
Medical Dosimetry
Volume 33, Issue 3
, Pages 215-221
, Autumn 2008
Comparison of IMRT Treatment Plans Between Linac and Helical Tomotherapy Based on Integral Dose and Inhomogeneity Index
References
- . Radiation-induced second cancers: the impact of 3D-CRT and IMRT. Int. J. Radiat. Oncol. Biol. Phys. 2003;56:83–88
- . The Physics of Radiology. 4th ed.. Springfield, IL: Thomas; 1983;
- Specifications of dose delivery in radiation therapy. Acta Oncol. 1997;36:1–32
- . Nontumor integral dose variation in conventional radiotherapy treatment planning. Med. Phys. 2003;30:2065–2071
- D'Souza, W.D.; Rosen, I. Variation of non-tumor integral dose in megavoltage photon beam treatment planning. Presented at the 44th AAPM Annual Meeting, July 14–18, 2002; Montreal, Canada.
- Biancia, C.D.; Hunt, M.; Amols, H. A comparison of the integral dose from 3D conformal and IMRT techniques in the treatment of prostate cancer. Presented at the 44th AAPM Annual Meeting, July 14–18, 2002; Montreal, Canada.
- Tao, L.; Rakfal, S.M.; Wu, A. Comparison of integral dose in conventional 2D, conformal 3D and IMRT plans. Presented at the 44th AAPM Annual Meeting, July 14–18; 2002; Montreal, Canada.
- TomoTherapy. Semin. Radiat. Oncol. 1999;9:108–117
- Helical TomoTherapy for craniospinal radiation. Br. J. Radiol. 2005;78:548–552
- Integral radiation dose to unspecified normal structure with conformal external beam radiation: A comparison between three-dimensional conformal radiotherapy and intensity modulated radiotherapy. Abstract No. 97 In: American Society of Clinical Oncology, Prostate Cancer Symposium. 2005;
- Reduction in radiation dose to lung and other normal tissues using helical tomotherapy to treat lung cancer, in comparison to conventional field arrangements. Am. J. Clin. Oncol. 2003;26:70–78
- . Integral dose in pediatric craniospinal irradiation with the helical TomoTherapy Hi-ART System. In: Mehta M, Paliwal BR, Bentzen S editor. Physical, Chemical & Biological Targeting in Radiation Oncology. Proceedings from the 7th International Conference on Dose, Time and Fractionation. 2005;p. 92–93
- . Evaluation of integral dose in cranio-spinal axis (CSA) irradiation with conventional and helical delivery. Technol. Cancer Res. Treat. 2005;4:683–690
- . Intensity-modulated radiation therapy (IMRT) dosimetry of the head and neck: A comparison of treatment plans using linear accelerator-based IMRT and helical tomotherapy. Int. J. Radiat. Oncol. Biol. Phys. 2006;65:917–923
- Dosimetric comparisons of helical tomotherapy treatment plans and step-and-shoot (Evaluation of two tomotherapy-based techniques for the delivery of whole-breast intensity-modulated radiation therapy). Int. J. Radiat. Oncol. Biol. Phys. 2006;65:608–616
- A comparison of prostate IMRT and helical tomotherapy class solutions. Radiother. Oncol. 2006;80:374–377
- Dosimetric comparison of helical tomotherapy treatment and step-and-shoot intensity-modulated radiotherapy of retroperitoneal sarcoma. Radiother. Oncol. 2006;81:81–87
- Comparison of advanced irradiation techniques with photons for benign intracranial tumours. Radiother. Oncol. 2006;80:268–273
- Dosimetric study and in-vivo dose verification for conformal avoidance treatment of anal adenocarcinoma using helical tomotherapy. Med. Dosim. 2007;32:33–37
- A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation. Radiother. Oncol. 2007;82:317–323
PII: S0958-3947(07)00212-9
doi: 10.1016/j.meddos.2007.11.001
© 2008 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Medical Dosimetry
Volume 33, Issue 3
, Pages 215-221
, Autumn 2008