Medical Dosimetry
Volume 35, Issue 1 , Pages 19-27 , Spring 2010

Measurement and Evaluation of Inhomogeneity Corrections and Monitor Unit Verification for Treatment Planning

  • Rishik Saxena, M.S.
  • ,
  • Patrick Higgins, Ph.D.

      Affiliations

    • Corresponding Author InformationReprint requests to: Patrick Higgins, Ph.D., Therapeutic Radiology-Radiation Oncology, University of Minnesota, 420 Delaware Street S.E., MMC 494, Minneapolis, MN 55455-0110

Received 23 July 2008 ,Accepted 2 January 2009.

References 

  1. Corrasco P, Jornet N, Duch M, et al. Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium. Med. Phys. 2004;31:2899–2911
  2. Jones A, Das I. Comparison of inhomogeneity correction algorithms in small photon fields. Med. Phys. 2005;32:766–776
  3. Arnfield M, Hartmann-Siantar C, Siebers J, et al. The impact of electron transport on the accuracy of computed dose. Med. Phys. 2000;7:1266–1274
  4. Saitoh H, Fujisaki T, Sakai R, et al. Dose distribution of narrow beam irradiation for small lung tumor. Int. J. Radiat. Oncol. Biol. Phys. 2002;53:1380–1387
  5. Sterpin E, Tomsej M, DeSmedt B, et al. Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator. Med. Phys. 2007;34:1665–1677
  6. Ding G, Duggan D, Lu B, et al. Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy. Med. Phys. 2007;34:2985–2994
  7. Knoos T, Wieslander E, Cozzi L, et al. Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations. Phys. Med. Biol. 2006;51:5785–5807
  8. Van Esch A, Tillikainen L, Pyykkonen J, et al. Testing of the analytical anisotropic algorithm for photon dose calculations. Med. Phys. 2006;33:4130–4148
  9. Tang W, Khan F, Gerbi B. Validity of lung correction algorithms. Med. Phys. 1986;13:683–686
  10. Batho H. Lung corrections in Cobalt-60 beam therapy. J. Can. Assoc. Radiol. 1964;15:79–83
  11. Sonta M, Cunningham J. Correction to absorbed dose calculations for tissue inhomogeneities. Med. Phys. 1977;4:431–436
  12. Sontag M, Cunningham J. The equivalent tissue-air ratio method for making absorbed dose calculation in a heterogeneous medium. Radiology. 1978;129:787–794
  13. Mah K, Van Dyk J. On the impact of tissue inhomogeneity corrections in clinical thoracic radiation therapy. Int. J. Radiat. Oncol. Biol. Phys. 1991;21:1257–1267
  14. Macki T, Scrimger J, Battista J. A convolution method of calculating dose for 15-MV x-rays. Med. Phys. 1985;12:169–177
  15. Papanikolaou N, Mackie T. A convolution/superposition algorithm for photon beam dose computation. 1997;World Congress on Medical Physics, Nice. V.35, Suppl. Part 2.; p. 915
  16. Ulme W, Pyyry J, Kaissl W. A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations. Phys. Med. Biol. 2005;50:1767–1790
  17. Fogliata A, Nicolini G, Vanetti E, et al. Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: Fundamental characterization in water. Phys. Med. Biol. 2006;51:1421–1438
  18. Schach von Wittenau A, Cox L, Bergstrom J, et al. Correlated histogram representation of Monte Carlo derived medical accelerator photon-output phase space. Med. Phys. 1999;26:1196–1211
  19. Nelson, W.; Hirayama, H.; Rogers, D. The EGS4 code system. SLAC report 265; 1985.
  20. Rogers D, Faddegon B, Ding X, et al. Beam: A Monte Carlo code to simulate radiotherapy treatment units. Med. Phys. 1995;22:503–524
  21. AAPM Report 85 (Report of Task Group No. 65 of the Radiation Therapy Committee of the American Association of Physicists in Medicine). Madison, WI: Medical Physics Publishing; 2004;
  22. Hubbell J. Photon mass attenuation and energy absorption coefficients from 1 keV to 20 MeV. Int. J. Appl. Radiat. Isotopes. 1982;33:1269
  23. Bedford J, Childs P, Nordmark Hansen V, et al. Commissioning and quality assurance of the Pinnacle3 radiotherapy treatment planning system for external beam photons. Br. J. Radiol. 2003;76:163–176

PII: S0958-3947(09)00002-8

doi: 10.1016/j.meddos.2009.01.002

Medical Dosimetry
Volume 35, Issue 1 , Pages 19-27 , Spring 2010