Medical Dosimetry
Volume 35, Issue 2 , Pages 115-121, Summer 2010

Adjuvant Radiotherapy for Gastric Cancer: A Dosimetric Comparison of 3-Dimensional Conformal Radiotherapy, Tomotherapy® and Conventional Intensity Modulated Radiotherapy Treatment Plans

Presented at The Canadian Association of Radiation Oncology 22nd Annual Scientific Meeting, September 10–13, 2008, Montreal, Quebec, Canada.

  • Max Dahele, M.B., Ch.B.

      Affiliations

    • Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
    • Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
  • ,
  • Matthew Skinner, M.Sc.

      Affiliations

    • Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
  • ,
  • Brenda Schultz, M.R.T.(T)

      Affiliations

    • Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
  • ,
  • Marlene Cardoso, M.R.T.(T)

      Affiliations

    • Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
  • ,
  • Chris Bell, M.R.T.(T)

      Affiliations

    • Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
  • ,
  • Yee C. Ung, M.D.

      Affiliations

    • Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
    • Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
    • Corresponding Author InformationReprint requests to: Yee C. Ung, M.D., University of Toronto Department of Radiation Oncology and Odette Cancer Centre, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, Toronto, Ontario, Canada M4N 3M5

Received 11 January 2009; accepted 10 March 2009. published online 21 May 2009.

Abstract 

Some patients with gastric cancer benefit from post-operative chemo-radiotherapy, but adequately irradiating the planning target volume (PTV) whilst avoiding organs at risk (OAR) can be difficult. We evaluate 3-dimensional conformal radiotherapy (CRT), conventional intensity-modulated radiotherapy (IMRT) and helical tomotherapy (TT). TT, 2 and 5-field (F) CRT and IMRT treatment plans with the same PTV coverage were generated for 5 patients and compared. Median values are reported. The volume of left/right kidney receiving at least 20Gy (V20) was 57/51% and 51/60% for 2 and 5F-CRT, and 28/14% for TT and 27/19% for IMRT. The volume of liver receiving at least 30Gy (V30) was 45% and 62% for 2 and 5F-CRT, and 37% for TT and 35% for IMRT. With TT, 98% of the PTV received 95-105% of the prescribed dose, compared with 45%, 34% and 28% for 2F-CRT, 5F-CRT and IMRT respectively. Using conventional metrics, conventional IMRT can achieve comparable PTV coverage and OAR sparing to TT, but at the expense of PTV dose heterogeneity. Both irradiate large volumes of normal tissue to low doses. Additional studies are needed to demonstrate the clinical impact of these technologies.

Key Words: Gastric cancer, Adjuvant radiotherapy, TomoTherapy, Intensity-modulated radiotherapy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0958-3947(09)00015-6

doi:10.1016/j.meddos.2009.03.003

Medical Dosimetry
Volume 35, Issue 2 , Pages 115-121, Summer 2010