Medical Dosimetry
Volume 36, Issue 1 , Pages 35-40, Spring 2011

Conkiss: Conformal Kidneys Sparing 3D Noncoplanar Radiotherapy Treatment for Pancreatic Cancer As an Alternative to IMRT

  • Zsolt Sebestyén, M.Sc.

      Affiliations

    • University of Pécs, Institute of Oncotherapy, Pécs, Hungary
    • Corresponding Author InformationReprint requests to: Zsolt Sebestyén, M.Sc., H-7624 Pécs, Édesanyák útja 17, Hungary
  • ,
  • Péter Kovács, M.Sc.

      Affiliations

    • University of Pécs, Institute of Oncotherapy, Pécs, Hungary
  • ,
  • Ákos Gulybán, M.Sc.

      Affiliations

    • EORTC Headquarters, Brussels, Belgium
  • ,
  • Róbert Farkas, M.D.

      Affiliations

    • University of Pécs, Institute of Oncotherapy, Pécs, Hungary
  • ,
  • Szabolcs Bellyei, M.D., Ph.D.

      Affiliations

    • University of Pécs, Institute of Oncotherapy, Pécs, Hungary
  • ,
  • Gábor Liposits, M.D.

      Affiliations

    • University of Pécs, Institute of Oncotherapy, Pécs, Hungary
  • ,
  • András Szigeti, M.D., Ph.D.

      Affiliations

    • University of Pécs, Institute of Oncotherapy, Pécs, Hungary
  • ,
  • Olga Ésik, M.D., D.Sc.

      Affiliations

    • University of Pécs, Institute of Oncotherapy, Pécs, Hungary
  • ,
  • Katalin Dérczy, M.D.

      Affiliations

    • University of Pécs, Department of Radiology, Pécs, Hungary
  • ,
  • László Mangel, M.D., Ph.D.

      Affiliations

    • University of Pécs, Institute of Oncotherapy, Pécs, Hungary

Received 4 June 2009; accepted 10 November 2009. published online 25 January 2010.

Abstract 

When treating pancreatic cancer using standard (ST) 3D conformal radiotherapy (3D-CRT) beam arrangements, the kidneys often receive a higher dose than their probable tolerance limit. Our aim was to elaborate a new planning method that—similarly to IMRT—effectively spares the kidneys without compromising the target coverage. Conformal kidneys sparing (CONKISS) 5-field, noncoplanar plans were compared with ST plans for 23 consecutive patients retrospectively. Optimal beam arrangements were used consisting of a left- and right-wedged beam-pair and an anteroposterior beam inclined in the caudal direction. The wedge direction determination (WEDDE) algorithm was developed to adjust the adequate direction of wedges. The aimed organs at risk (OARs) mean dose limits were: kidney <12 Gy, liver <25 Gy, small bowels <30 Gy, and spinal cord maximum <45 Gy. Conformity and homogeneity indexes with z-test were used to evaluate and compare the different planning approaches. The mean dose to the kidneys decreased significantly (p < 0.05): left kidney 7.7 vs. 10.7 Gy, right kidney 9.1 vs. 11.7 Gy. Meanwhile the mean dose to the liver increased significantly (18.1 vs. 15.0 Gy). The changes in the conformity, homogeneity, and in the doses to other OARs were not significant. The CONKISS method balances the load among the OARs and significantly reduces the dose to the kidneys, without any significant change in the conformity and homogeneity. Using 3D-CRT the CONKISS method can be a smart alternative to IMRT to enhance the possibility of dose escalation.

Key Words: Pancreatic cancer, 3D conformal radiotherapy, Noncoplanar fields, Dosimetric comparison, IMRT

 

PII: S0958-3947(09)00127-7

doi:10.1016/j.meddos.2009.11.001

Medical Dosimetry
Volume 36, Issue 1 , Pages 35-40, Spring 2011