Medical Dosimetry
Volume 36, Issue 1 , Pages 102-108 , Spring 2011

Re-Planning for Compensator-Based IMRT with Original Compensators

Presented at the World Congress of Medical Physics and Biomedical Engineering, Munich, Germany, September 7–12, 2009

Received 8 July 2009 ,Accepted 10 January 2010.

References 

  1. Xia P, Verhey LJ. Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments. Med. Phys. 1998;25:1424–1434
  2. Chang SX, Cullip TJ, Deschesne KM, et al. Compensators: An alternative IMRT delivery technique. J. Appl. Clin. Med. Phys. 2004;5:15–36
  3. Chang S, Deschesne K, Chen H, et al. A multi-institutional retrospective study on clinical IMRT treatment delivery efficiency. Med. Phys. 2008;35:2746
  4. Tyagi A, Nangia S, Chufal K, et al. Quality assurance and dosimetric analysis of intensity modulated radiotherapy using compensators for head and neck cancers. Med. Phys. 2008;35:2763
  5. Tang X, Tyagi N, Wang J, et al. Dosimetric comparison of compensator and multi-leaf collimator (MLC) based intensity modulated radiosurgery (IMRS). Med. Phys. 2008;35:2826
  6. Chang S, Levinson L, Potter L, et al. Comparison of compensator-IMRT and segmental MLC-IMRT techniques: A retrospective study on treatment time, monitor units, and dosimetry in clinical application. Med. Phys. 2007;34:2428
  7. Ahunbay E, Li XA. Investigation of the reliability, accuracy, and efficiency of gated IMRT delivery with a commercial linear accelerator. Med. Phys. 2007;34:2928–2938
  8. Chang SX, Cullip TJ, Deschesne KM. Intensity modulation delivery techniques: “Step & shoot” MLC auto-sequence versus the use of a modulator. Med. Phys. 2000;27:948–959
  9. Mu X, Lf̈roth P-O, Karlsson M, et al. The effect of fraction time in intensity modulated radiotherapy: Theoretical and experimental evaluation of an optimisation problem. Radiother. Oncol. 2003;68:181–187
  10. Hansen EK, Bucci MK, Quivey JM, et al. Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer. Int. J. Radiat. Oncol. Biol. Phys. 2006;64:355–362
  11. Kestin LL, Sharpe MB, Frazier RC, et al. Intensity modulation to improve dose uniformity with tangential breast radiotherapy: Initial clinical experience. Int. J. Radiat. Oncol. Biol. Phys. 2000;48:1559–1568
  12. Perez CA, Einhorn L, Oldham RK, et al. Randomized trial of radiotherapy to the thorax in limited small-cell carcinoma of the lung treated with multiagent chemotherapy and elective brain irradiation: A preliminary report. J. Clin. Oncol. 1984;2:1200–1208

PII: S0958-3947(10)00013-0

doi: 10.1016/j.meddos.2010.01.004

Medical Dosimetry
Volume 36, Issue 1 , Pages 102-108 , Spring 2011