Monitor Unit Checking in Heterogeneous Stereotactic Body Radiotherapy Treatment Planning

  • Patrick D. Higgins, Ph.D.

      Affiliations

    • Department of Therapeutic Radiology–Radiation Oncology, University of Minnesota Medical School, Minneapolis, MN
    • Corresponding Author InformationReprint requests to: Patrick D. Higgins, Ph.D., Department of Therapeutic Radiology–Radiation Oncology, University of Minnesota Medical School, Mayo Mail Code 494, Minneapolis, MN 55455-0110
  • ,
  • Troy Adolfson, M.D.

      Affiliations

    • Department of Therapeutic Radiology–Radiation Oncology, University of Minnesota Medical School, Minneapolis, MN
  • ,
  • L. Chinsoo Cho, M.D.

      Affiliations

    • Department of Therapeutic Radiology–Radiation Oncology, University of Minnesota Medical School, Minneapolis, MN
  • ,
  • Rishik Saxena, M.S.

      Affiliations

    • Department of Radiation Oncology, Abbott Northwestern Hospital, Minneapolis, MN

Received 7 December 2009; accepted 27 April 2010. published online 21 June 2010.

Abstract 

Treatment of lung cancer using very-high-dose fractionation in small fields requires well-tested dose modeling, a method for density-averaging compound targets constructed from different parts of the breathing cycle, and monitor unit verification of the heterogeneity-corrected treatment plans. The quality and safety of each procedure are dependent on these factors. We have evaluated the dosimetry of our first 26 stereotactic body radiotherapy (SBRT) patients, including 260 treatment fields, planned with the Pinnacle treatment planning system. All targets were combined from full expiration and inspiration computed tomography scans and planned on the normal respiration scan with 6-MV photons. Combined GTVs (cGTVs) have been density-averaged in different ways for comparison of the effect on total monitor units. In addition, we have compared planned monitor units against hand calculations using 2 classic 1D correction methods: (1) effective attenuation and (2) ratio of Tissue-Maximum Ratios (TMRs) to determine the range of efficacy of simple verification methods over difficult-to-perform measurements. Different methods of density averaging for combined targets have been found to have minimal impact on total dose as evidenced by the range of total monitor units generated for each method. Nondensity-corrected treatment plans for the same fields were found to require about 8% more monitor units on average. Hand calculations, using the effective attenuation method were found to agree with Pinnacle calculations for nonproblematic fields to within ±10% for >95% of the fields tested. The ratio of TMRs method was found to be unacceptable. Reasonable choices for density-averaging of cGTVs using full inspiration/expiration scans should not strongly affect the planning dose. Verification of planned monitor units, as a check for problematic fields, can be done for 6-MV fields with simple 1D effective attenuation-corrected hand calculations.

Key Words: SBRT, Dose verification, Density effects

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0958-3947(10)00066-X

doi:10.1016/j.meddos.2010.04.003

Medical Dosimetry
Volume 36, Issue 3 , Pages 255-263, Autumn 2011