Medical Dosimetry
Volume 22, Issue 3 , Pages 219-225, Autumn 1997

Implementation of Enhanced Dynamic Wedge into the Multidata DSS Radiotherapy Treatment Planning System

  • A.W. Beavis, Ph.D., BSc, Minstp, CPhys.

      Affiliations

    • Corresponding Author InformationReprint requests to: A. W. Beavis, Ph.D., Princess Royal Hospital, Department of Radiation Physics, Saltshouse Road, Hull, England HU8 9HE, UK.
    • Department of Radiation Physics (Royal Hull Hospitals NHS Trust) Hull, HU8 9HE England, UK
    • Academic Department of Medical Physics (University of Hull), Princess Royal Hospital, Saltshouse Road, Hull, HU8 9HE England, UK

Abstract 

The Radiotherapy Treatment Planning (RTP) system used in Hull is the Multidata Decision Support System version 2.35 (Multidata Systems Intl. Corp., St. Louis, MO). The implementation philosophy described herein relates to the software version listed above, utilizing the “Revision A Wedge” routines and requires no additional “Dynamic Wedge” software module. The Enhanced Dynamic Wedge (EDW) is entered into the system as if it were a hard wedge. The RTP system uses a Bentley-Milan algorithm and we have shown that our implementation of EDW into the Multidata commercial planning system is consistent with this philosophy and works very well. This report will cover required beam data, validation (Quality control) of the profiles produced by the RTP computations and calculation of wedge factors (hence Monitor Units) for a general EDW field. The beam data collection was performed without the use of sophisticated measurement equipment such as linear diode arrays or ion chamber arrays, hence the methodology is designed to be as user friendly as possible and to require only a small set of data.

Keywords:  Radiotherapy planning, dynamic wedge

No full text is available. To read the body of this article, please view the PDF online.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0958-3947(97)00022-8

Medical Dosimetry
Volume 22, Issue 3 , Pages 219-225, Autumn 1997