Investigation of dose profile across the junction of deep inspiration breath hold, breast with supra-clavicle fossa treatments

      ABSTRACT

      Breast with supraclavicular fossa (Br+SCF) radiotherapy treatments can utilise a monoisocentric technique to concurrently treat the breast area (tangent fields) and supraclavicular area (opposing fields). The region where these treatment areas adjoin is known as the junction region, field junction, or match line. Dose variations that may occur about the junction region, due to geometrical inaccuracies, are typically feathered out in patient free-breathing treatments. However, there is limited information on how dose at the junction is influenced in deep inspiration breath hold (DIBH) treatments. This study aims to investigate dose variation at the field junction for a patient population undertaking a DIBH Br+SCF treatment course. GAFChromic EBT3 film was used to record the dose across the junction at skin surface for approximately one third of the 25 fraction treatment course for 11 patients undergoing DIBH Br+SCF treatment. Single fraction and summated fraction profiles for each patient were compared to profiles in the treatment planning system and assessed the: (1) local dose variations, (2) position of the 50% dose gradient, and (3) relative dose at the nominal junction. Local dose variations of 10% or greater, position displacement of the junction greater than 5 mm, and relative dose differences at the match line greater than 10% can be found within single fraction dose profiles. When these single fractions are summed over the treatment course, the position variations reduce to 2 mm and dose variations reduced to within 10% for 10 of the 11 patients. Only one of 11 patients recorded a summed dose difference greater than ±10% over their treatment, recording 76% ± 8% of the planned dose in this region. This was due to a small overall position displacement of 1.8 ± 1.6 mm from the nominal junction. A feathering of the dose at the junction is present for DIBH Br+SCF patient treatments. The feathering effect is sufficient, in the majority of cases studied, to reduce any differences in dose and displacement present in single fractions. This work also demonstrates that there may be exceptions from this observed behavior that should be considered. Further study in this area using a larger patient cohort is recommended.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Medical Dosimetry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Mayles P
        • Nahum A
        • Rosenwald J-C
        Handbook of Radiotherapy Physics. 33. CRC Press, Boca Raton, FL2007: 681-699
        • Banaei A
        • Hashemi B
        • Bakhshandeh M.
        Comparing the monoisocentric and dual isocentric techniques in chest wall radiotherapy of mastectomy patients.
        JACMP. 2015; 16: 130-138
        • Miles E
        • Venables K
        • Hoskin P
        • et al.
        Dosimetry and field matching for radiotherapy to the breast and supraclavicular fossa.
        Radiother Oncol. 2009; 91: 42-48
        • Mahmoud A
        • Somayeh N
        • Mahbod E
        • et al.
        Optimization of three dimensional planning dosimetric in breast phantom for match region of supraclavicular and tangential fields.
        J Cancer Res Ther. 2013; 9: 64-70
        • Kagkiouzis J
        • Platoni K
        • Kantzou I
        • et al.
        Review of the three-field techniques in breast cancer radiotherapy.
        JBUON. 2017; 22: 599-605
        • Idzes M
        • Holmberg O
        • Mijnheer B
        • et al.
        Effect of set-up uncertainties on the dose distribution in the match region of supraclavicular and tangential breast fields.
        Radiother Oncol. 1998; 46: 91-98
        • Claridge-Mackonis E
        • Estoesta R
        • Carroll S.
        In-vivo dosimetry comparison of supraclavicular junction dose for breast and chest-wall patients with and without deep inspiration breath hold (DIBH).
        Phys Medica. 2018; 54: 15-20
        • Rutqvist L
        • Johansson H.
        Mortality by laterality of the primary tumour among 55,000 breast cancer patients from the Swedish Cancer Registery.
        Brit J Cancer. 1990; 61: 866-868
        • Henson K
        • McGale P
        • Taylor C
        • et al.
        Radiation-related mortality from heart disease and lung cancer more than 20 years after radiotherapy for breast cancer.
        Brit J Cancer. 2013; 108: 179-182
        • Darby S
        • Ewertz M
        • McGale P
        • et al.
        Risk of ischemic heart disease in women after radiotherapy for breast cancer.
        New Engl J Med. 2013; 368: 987-998
      1. eviQ Cancer Treatments Online. Radiation associated cardiac disease. eviQ. [Online] Cancer Institute NSW, 13 06 2019. [Accessed: 27 06 2021.] Available at: https://www.eviq.org.au/clinical-resources/radiation-oncology/side-effect-and-toxicity-management/1773-radiation-associated-cardiac-disease#assessment.

        • Bovelli D
        • Plataniotis G
        • Roila F
        Cardiotoxicity of chemotherapeutic agents and radiotherapy-related heart disease: ESMO clinical practice guidelines.
        Ann Oncol. 2010; 21 (On behalf of the ESMO Guidelines Working Group.): 277-282
      2. Cancer Institute NSW. Breast invasive cancer adjuvant nodal irradiation EBRT. eviQ.[Online] 13 06 2019. [Accessed: 27 06 2021.] Available at: https://www.eviq.org.au/radiation-oncology/breast/1924-breast-invasive-cancer-adjuvant-nodal-irradia#organs-at-risk.

        • Latty D
        • Stuart K
        • Wang W
        • et al.
        Review of deep inspiration breath-hold techniques for the treatment of breast cancer.
        J Med Radiat Sci. 2015; 62: 74-81
        • Bergom C
        • Currey A
        • Desai N
        • et al.
        Deep inspiration breath hold: techniques and advantages for cardiac sparing during breast cancer irradiation.
        Front Oncol. 2018; 8: 1-10
        • Smyth L
        • Knight K
        • Aarons Y
        • et al.
        The cardiac dose-sparing benefits of deep inspiration breath-hold in left breast irradiation: a systematic review.
        J Med Radiat Sci. 2015; 62: 66-73
        • Darapu A
        • Balakrishnan R
        • Sebastian P
        • et al.
        Is the deep inspiration breath-hold technique superior to the free breathing technique in cardiac and lung sparing while treating both left-sided post-mastectomy chest wall and supraclavicular regions?.
        Case Rep Oncol. 2017; 10: 37-51
        • Kapanen M
        • Laaksomaa M
        • Pehkonen J
        • et al.
        Effects of multiple breath hold reproducibility on treatment localization and dosimetric accuracy in radiotherapy of left-sided breast cancer with voluntary deep inspiration breath hold techique.
        Med Dosim. 2017; 42: 177-184
      3. International Specialty Products. Gafchromic EBT3 user guidelines.

        • American Association of Physicists in Medicine
        AAPM Report No 60 - Instrumentation requirements of diagnostic radiological physicists.
        Med Phys. 1998;
        • Kairn T
        • Aland T
        • Kenny J.
        Local heterogeneities in early batches of EBT2 film: a suggested solution.
        Phys Med Biol. 2010; 55: L37-L42
        • Marroquin E
        • Gonzalez J
        • Lopez M
        • et al.
        Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density.
        J ACMP. 2016; 17: 466-481
        • Huq S
        • Fraass B
        • Dunscombe P
        • et al.
        The report of task group 100 of the AAPM: application of risk analysis methods to radiation therapy quality management.
        Med Phys. 2016; 43: 4209-4262
        • Agency, International Atomic Energy
        Technical Reports Series No 430: Commissioning and quality assurance of computerized planning systems for radiation treatment of cancer.
        IAEA. 2004;
        • Court L
        • Tishler R
        • Allen A
        • et al.
        Experimental evaluation of the accuracy of skin dose calculation for a commercial treatment planning system.
        JACMP. 2008; 9 (Vol): 29-35
        • Oinam A
        • Singh L.
        Verification of IMRT dose calculations using AAA and PBC algorithms in dose buildup regions.
        JACMP. 2010; 11: 105-121