Research Article| Volume 47, ISSUE 3, P252-257, September 2022

A dosimetric comparison of 3D DCAT vs VMAT for palliative and early-stage liver lesions using eclipse TPS

      Abstract

      Volumetric modulated arc therapy (VMAT) and 3D dynamic conformal arc therapy (DCAT) are 2 methods proven useful for the clinical implementation of stereotactic body radiation therapy (SBRT) for lung lesions however, similar comparisons of SBRT liver lesions are lacking. The purpose of this study was to determine if the conformity of dose, irradiated volume, and dose to organs at risk (OAR) are equivalent or improved with the use of DCAT as an alternative treatment method when compared to standard VMAT for SBRT delivery of palliative and early-stage liver lesions. Twenty patients with liver lesions sized 2.0 to 5.0 cm were selected for this study. Plans were created with both DCAT and VMAT techniques for each patient. Metrics evaluated included the mean heart, kidney, large bowel, small bowel, esophagus, and stomach doses, the lung volume receiving 20 Gy (V20), the volume of the normal liver receiving 15 Gy (V15), conformity index (CI), heterogeneity index (HI), and the irradiated volume or volume receiving 25 Gy (V25). The p-values for the mean dose to kidneys, small bowel, esophagus, and the lung V20 were greater than 0.05, and no statistical difference could be determined between DCAT and VMAT. The p-values for the mean heart, large bowel, stomach, and liver V15 were less than 0.05, indicating statistical significance and superiority of VMAT for minimizing dose to these organs, especially V15 of the liver. The DCAT technique produced CI greater than 1.0 for all patients proving superior coverage, while standard VMAT produced significantly improved V25 with p-values less than 0.0001, and consequently higher HI.

      Keywords

      Introduction

      The liver is a precarious site for various comorbidities and metastatic diseases alike as a major recipient of damage from conditions ranging from obesity, viruses, and excessive alcohol consumption to advanced colorectal cancer. An aggregation of 2020 cancer statistics showed a consistent, yearly increase of primary liver cancer incidence by 2.0% to 3.0%, with death rates also following a similar trend.
      • Siegel RL
      • Miller KD
      • Jemal A.
      Cancer statistics, 2020.
      Advancement in radiation oncology have played a critical role in the selection of volumetric modulated arc therapy (VMAT) over 3D-conventional radiation therapy (3D-CRT) in an effort to treat liver lesions and spare normal tissue. Dynamic conformal arc therapy (a form of 3D-CRT) and VMAT methods are popular researched techniques being clinically applied for SBRT of the lung, with some even suggesting a hybrid of the two to maximize benefits of each method.
      • Han L
      • Sintay B
      • Pearman K
      • et al.
      A hybrid planning strategy for stereotactic body radiation therapy of early stage non-small-cell lung cancer.
      However, there is a lack of direct comparisons, consensus, and analysis regarding the 2 methods for SBRT of the liver.
      The advantages and disadvantages of VMAT and DCAT differ in that the former method uses optimization of multi-leaf collimators (MLCs) while the latter does not. The primary advantages of VMAT include the ability to achieve dose conformity, lower overall toxicity, and better spare OAR including nonliver organs and those low dose tolerances such as the lung.
      • Afrin KT
      • Ahmad S.
      Is IMRT or VMAT superior or inferior to 3D conformal therapy in the treatment of lung cancer? A brief literature review.
      ,
      • Bae SH
      • Jang WI
      • Park HC.
      Intensity-modulated radiotherapy for hepatocellular carcinoma: dosimetric and clinical results.
      However, IMRT methods are also known to produce an increase of low dose, including the volume of the normal liver receiving 15 Gy (V15), which is thought to be one dosimetric indicator for predicting radiation-induced liver disease (RILD).
      • Bae SH
      • Jang WI
      • Park HC.
      Intensity-modulated radiotherapy for hepatocellular carcinoma: dosimetric and clinical results.
      Volumetric modulated arc therapy is also associated with an increased interplay effect caused by the motion of the liver during breathing cycles and is reported to result in significant intra-fraction variability (> 3.0 mm), exacerbated by flattening filter-free (FFF) beams and smaller clinical target volumes (CTV).
      • Tsai YL
      • Wu CJ
      • Shaw S
      • Yu PC
      • Nien HH
      • Lui LT.
      Quantitative analysis of respiration-induced motion of each liver segment with helical computed tomography and 4-dimensional computed tomography.
      • Lu L
      • Diaconu C
      • Djemil T
      • et al.
      Intra- and inter-fractional liver and lung tumor motions treated with SBRT under active breathing control.
      • Edvardsson A
      • Nordstrom F
      • Ceberg C
      • Ceberg S.
      Motion induced interplay effects for VMAT radiotherapy.
      Alternatively, DCAT compensates for the disadvantages of VMAT but does have clear disadvantages in clinical application of treatments involving irregularly shaped target volumes because intensity modulation is not utilized. The DCAT method follows the principle of a 3D conformal radiation treatment, where MLCs are not optimized to modulate for elimination of hot spots. Instead, 3D methods are open to a strict margin outside the target to allow adequate coverage while sparing nearby organs. The DCAT method incorporates the 3D fundamentals into an arc form, using multiple angles to improve conformality around the target. Due to the ablative nature of SBRT liver treatments, the occurrence of hot spots > 110% is normal and acceptable, which has contributed to a rise of DCAT for SBRT lung treatments. The nature of a SBRT method combined with the potential improvements of the drawbacks of VMAT methods mentioned, DCAT may offer an alternative solution to SBRT for small or early staged liver lesions in the condition that it can produce plans of equal or better quality than that of VMAT.
      Specific to SBRT lung treatments, comparisons using VMAT and DCAT have shown that DCAT had similar conformity and coverage of the early-stage tumor, with slightly better avoidance of OAR which included the lung volume receiving 20 Gy (V20), tighter 50% isodose lines, and a significant reduction of monitor units (MUs).
      • Pokhrel D
      • Visak J
      • Sanford L.
      A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT.
      Segment weight-optimized (SWO) DCAT produced dosimetrically similar plans to VMAT in favorable conditions where the tumor was not directly adjacent to OAR.
      • Bokrantz R
      • Wedenberg M
      • Sandwall P.
      Dynamic conformal arcs for lung stereotactic body radiation therapy: a comparison with volumetric-modulated arc therapy.
      In addition to its technical simplicity, DCAT is more likely to be approved by insurance in general due to the rising cost-benefit ratio of VMAT and therefore provides timely palliative treatment of the liver. Currently, there is a lack of accessibility to policies and comparison data needed to draw a consensus on insurance coverage of the liver with different modes of radiation delivery.
      • Verma V
      • Ludmir EB
      • Mesko SM
      • et al.
      Commercial insurance coverage of advanced radiation therapy techniques compared with American society for radiation oncology model policies.
      ,
      • Roach MC
      • TO Thomas
      • Paravati AJ
      • Mahajan A.
      Differences in United States insurance payer policies and American society for radiation oncology's (ASTRO) model policy on stereotactic body radiation therapy (SBRT).
      In 2 emerging studies, researchers have observed VMAT vs DCAT for a variety of SBRT liver treatments. Moon et al.
      • Moon YM
      • Jeon W
      • Yu T
      • et al.
      Which is better for liver SBRT: dosimetric comparison between DCAT and VMAT for liver tumors.
      showed that the DCAT plan using segment shape optimization (SSO) met planning goals set by the Radiation Therapy Oncology Group (RTOG) SBRT liver protocols; although VMAT was slightly superior in dose distributions to some organs. Researchers also emphasized that, with DCAT, there is less chance of miss because the tumor is in an open field, and there is less concern with quality assurance, calculation, and interplay effect of the MLC leaves.
      • Roach MC
      • TO Thomas
      • Paravati AJ
      • Mahajan A.
      Differences in United States insurance payer policies and American society for radiation oncology's (ASTRO) model policy on stereotactic body radiation therapy (SBRT).
      Although the study by Moon et al.
      • Moon YM
      • Jeon W
      • Yu T
      • et al.
      Which is better for liver SBRT: dosimetric comparison between DCAT and VMAT for liver tumors.
      demonstrated the coverage, conformity, and doses to some OAR using VMAT and DCAT for liver lesions varying in size and number, the authors did not investigate the dose to the kidneys, bowels, lung, and V15 of the normal liver, which is critical for safe deliverability of a SBRT liver treatment. This study also uses Monaco for treatment planning, which uses optimization for beam weighting and segment shaping. Thaper et al.
      • Thaper D
      • Kamal R
      • Singh G
      • et al.
      Dosimetric comparison of dynamic conformal arc integrated with segment shape optimization and variable dose rate versus volumetric modulated arc therapy for liver SBRT.
      also observed a reduction in MU with DCAT but did not find the use of segment shape optimized (SSO) DCAT as advantageous in their clinical evaluation of DCAT vs VMAT for SBRT treatment of the liver; especially for larger planning target volume (PTV) sizes. With recent studies showing the ability of modified 3D-CRT methods such as the use of DCAT to mimic the results of VMAT plans, additional research is required to evaluate the efficacy and applicability of traditional 3D DCAT for SBRT delivery to treat limited sized liver tumors and compare the dose to nearby structures such as the gastrointestinal organs, normal liver, kidneys, heart, and lung are affected.
      Dynamic arc conformal therapy is used for both early-staged and palliative lung tumors due to the physical similarity in size. However, it is possible that the same is true of VMAT for early staged or small metastatic lesions in the liver. It would be beneficial to understand the differences of DCAT and VMAT in the treatment of liver lesions, especially with the increasing demand for optimization and inverse planning which contributes to increasing costs for IMRT as well as cost discrepancies between VMAT and 3D planning.
      • Piana R.
      Rising costs in radiation oncology linked to medicare coverage.
      The problem is that there is a paucity of literature comparing 3D DCAT to VMAT for early-stage or small metastatic liver lesions. Therefore, the purpose of this study was to determine if the conformity of dose, irradiated volume, and dose to OAR are equivalent or improved with the use of 3D DCAT as an alternative method of treatment when compared to standard VMAT for SBRT treatment of liver lesions. Researchers tested the hypotheses that 3D DCAT for liver lesions will achieve mean doses to (H1A) the heart, (H2A) kidney, (H3A) large bowel, (H4A) small bowel, (H5A) stomach, and (H6A) esophagus, ≤ to those created with VMAT; (H7A) V20 of the lungs will be ≤ those created by VMAT; (H8A) V15 < 700 cc to the normal liver; (H9A) conformity index (CI) ≥ 1; (H10A) homogeneity index (HI) ≤ 2; and (H11A) total irradiated volume or the volume receiving 25 Gy (V25) ≤ that of VMAT.

      Methods and Materials

      Patient selection

      Twenty patients with early-stage liver cancer or metastatic liver lesions from a single institution were retrospectively selected for this study. Inclusion criteria were patients between the ages of 45 and 85 years old and liver lesions measuring between 2.0 and 5.0 cm in the greatest dimension. Patients with lesions smaller or greater than 2.0 and 5.0 cm were not included in the study. Of the 20 patients selected, 12 had early-stage liver cancer and 8 had metastatic liver lesions. (Table 1).
      Table 1Patient characteristics including age, tumor size, and stage of disease
      Patient
      Anonymized and randomized patient data. Each patient's anonymized data set was randomly assigned a number.
      AgeTumor size (cm2)Early vs Metastatic
      1703.1 × 2.2Early
      2693.1 × 2.6Early
      3803.4 × 3.8Early
      4594.6 × 4.7Metastatic
      5783.3 × 2.8Early
      6732.7 × 2.5Metastatic
      7742.7 × 2.3Early
      8784.3 × 4.2Early
      9652.3 × 2.0Metastatic
      10693.6 × 2.8Early
      11654.6 × 3.8Early
      12702.6 × 2.6Early
      13592.4 × 2.8Metastatic
      14603.7 × 4.3Early
      15613.3 × 3.4Early
      16854.1 × 3.9Early
      17453.1 × 3.4Metastatic
      18503.5 × 3.9Metastatic
      19462.6 × 3.9Metastatic
      20532.8 × 2.9Metastatic
      # Anonymized and randomized patient data. Each patient's anonymized data set was randomly assigned a number.

      Patient setup

      Due to the location and type of treatment performed, extensive immobilization was used during CT simulation and throughout treatments to minimize internal organ motion. Use of increased immobilization allowed for treatment margins to be drawn tighter around tumors, helping to reduce potential dose to surrounding critical structures. During CT simulation, a Civco board was attached to the simulation table which was used to secure immobilization devices for SBRT. A Q-Fix knee sponge was indexed on the board for patient comfort and to keep the patient's lower anatomy stable. An arm shuttle was placed superiorly to the trunk of the patient, with the patient's head resting on the head rest of the arm shuttle, and their arms bent superiorly to the patient's head to keep them out of treatment fields. A full-body vacuum bag was placed under the patient's entire body, from about mid-thigh to their arms. The vacuum bag was immobilized completely around the patient to refrain the patient from any movement during treatment. Finally, a compression belt was used to apply pressure to the patient's abdominal region to shrink the range of motion of the abdomen and chest during the breathing cycle, thus reducing internal motion of organs. Breathing cycles were also tracked using 4D motion sensors; however, the plan was contoured, planned, and treated using the average of this cycle. There were no metallic components of any immobilization used, therefore these devices did not affect the dose of the treatment plan.

      Contouring

      After CT simulation, the datasets were imported into Varian Eclipse 15.6 Treatment Planning System (TPS) for contouring and fusions with other imaging studies to aid in delineation of the target volumes for the radiation oncologist. Contouring and fusions were done on the average breathing cycle from the 4D scan. Planning objectives, target volumes, and critical structures were partly adopted from RTOG 1112 protocol; therefore, the OAR contoured were the kidneys, small bowel, large bowel, esophagus, stomach, heart, and lungs.
      • Dawson L.
      Randomized phase III study of sorafenib versus stereotactic body radiation therapy followed by sorafenib in hepatocellular carcinoma.

      Treatment planning

      Treatment planning for each technique was consistent for all patients. AcurosXB version 13.7 of Varian Eclipse 15.6 TPS was utilized for the planning aspect of each patient's conformal and VMAT plans. Treatments were planned for a Varian TrueBeam linear accelerator with 120 HD MLCs. Both VMAT and DCA plans were designed using the energy 10 MV FFF for each field. 10 MV FFF was used over 6 MV FFF because of the small size of the lesions, the increased penetration, and dose rate this beam energy provides. The increased dose rate allows for faster treatments (2400 compared to 1400), less patient time on the table, and reduced patient movement error. The 10 FFF also can produce tighter 50% isodose lines. Stereotactic body radiation therapy treatment parameters were used for both techniques. Both VMAT and DCAT plans were planned for 50 Gy in 5 fractions. Based on the location of the tumor, beam arrangements for VMAT and DCAT techniques slightly differed for each patient to avoid excessive radiation to normal structures. The VMAT plans were designed with 2 to 3 partial arcs approximately 200 to 220° each. Slight collimator rotations were used to maximize MLC blocking based on the tumor volume. The size of the treatment volume also led to variable field sizes between patients. The DCAT plans were also designed consistently, with slight variance between patients due to tumor location. The DCA plans were designed to use 3 partial arcs. The order of the partial arcs was a 40° arc, a 5° gap, a 135° arc, another 5° gap, and a 40° arc. The weighting for the 135° arc was weighted 65% to 70% of the total dose. The weighting for the 40° arcs was equally weighted with the remaining dose. Collimator rotations and variable field sizes were also used based on the tumor volume and location. Both planning techniques were normalized to 100% of the prescription dose covering 95% of the treatment volume. For the DCAT method using Eclipse, it is important to note that it does not include any algorithm-based modulation of segments or optimization of beam weighting.

      Plan comparison

      After retrospectively planning VMAT and DCA techniques for each patient, coverage of the treatment volume was compared between the 2 techniques by analyzing the isodose lines and dose-volume histogram (DVH). Since both techniques were normalized to the same value, the isodose lines and dose fall-off were considered and compared between the 2 plans. Conformity index and V25 of the treatment volume were both calculated through Eclipse treatment planning software for each plan. Homogeneity index (HI) for each plan was derived from the equation, in which Imax is the maximum dose in the target and RI is the prescription isodose
      • Stanley J
      • Breitman K
      • Dunscombe P
      • Spencer DP
      • Lau H.
      Evaluation of stereotactic radiosurgery conformity indices for 170 target volumes in patients with brain metastases.
      :
      HI=Imax/RI
      (1)


      Dose metrics were also compared between the VMAT and DCA plans. The comparative dose metrics included: the mean dose of the heart, kidney, stomach, esophagus, small and large bowel; the V20 of the lungs; and the V15 of the liver. For each plan using either VMAT or DCAT technique, the dose metrics and dose values were acquired and compared (Eq. 1).

      Statistical analysis

      The raw data for all patients in the study were congregated to find the mean difference and standard deviation resulting from VMAT and DCAT plans. The mean difference was defined as the average difference of either dose, volume, or index values that resulted from VMAT minus DCAT. To test the significance of the mean difference values, a Wilcoxon test and paired t-test were performed utilizing IBM SPSS software. The Wilcoxon test was used to calculate the p values for mean doses to the heart, kidney, large bowel, small bowel, and also the V20 of the lungs. The paired t-test was used to calculate the p values for mean doses to the esophagus and stomach, V15 of the liver, CI, HI, and V25 of the treatment volume.

      Results

      Mean dose to organs at risk

      The mean dose difference to the heart, kidneys, large bowel, small bowel, stomach, and esophagus resulting from VMAT minus DCAT were -26.30, -1.01, -32.88, -2.82, -37.5, and -4.81 cGy, respectively (Table 2). The higher mean dose difference correlated with a larger range for standard deviation. The greatest mean dose differences were to the heart, large bowel, and stomach resulted in p values of 0.0046, 0.0023, and 0.0353, respectively. These p-values (< 0.05) indicated statistical significance between the 2 outcomes and that DCAT is not able to produce mean doses equivalent to that of VMAT for the heart, large bowel, and stomach; therefore, the null hypotheses cannot be rejected. Furthermore, the negative values of the mean difference indicated that the VMAT mean dose to the heart (H1A), large bowel (H3A), and stomach (H5A) was statistically lower than that of DCAT. The p-values for the kidneys, small bowel, and esophagus were 0.0696, 0.3223, and 0.792, respectively. These p-values (> 0.05) indicated that there was no statistical significance between the VMAT and DCAT plans suggesting that DCAT is not able to produce mean doses equivalent to that of VMAT for the kidneys, small bowel, and esophagus; therefore, the null hypotheses were rejected.
      Table 2Average mean difference of all VMAT and DCAT plans, standard deviation, and p-value for heart, kidneys, large bowel, small bowel, stomach, esophagus, lungs, and liver
      OARMean difference (cGy)Standard deviationp-value
      Heart-26.3048.240.0046
      p-value of mean difference is statistically significant, VMAT < DCAT
      Kidneys-1.017.500.0696
      Large Bowel-32.8859.150.0023
      p-value of mean difference is statistically significant, VMAT < DCAT
      Small Bowel-2.8217.290.3223
      Stomach-37.574.010.0353
      p-value of mean difference is statistically significant, VMAT < DCAT
      Esophagus-4.8180.410.792
      VMAT, Volumetric modulated arc therapy; DCAT, Dynamic conformal arc therapy; OAR, Organs at Risk; cGy, centigray.
      low asterisk p-value of mean difference is statistically significant, VMAT < DCAT

      Critical metrics

      To determine the overall safety and efficacy of the plan, the V20 of the lungs, V15 of the liver, CI, HI, and the V25 of the total volume were analyzed. The mean dose difference to the V20 of the lungs, V15 of the liver, CI, HI, and V25 of the total volume resulting from VMAT minus DCAT were –0.06, –61.73, -0.18, 0.06, and –46.30, respectively. The p-value of the V20 of the lungs (p = 0.2622) indicated that there was no statistical difference between the VMAT and DCAT plans and that DCAT was able to produce V20 of the lungs ≤ that of VMAT; therefore, the null hypothesis was rejected. The p-value of the V15 of the liver (< 0.0001,) indicated that the V15 of the liver (H8A) produced by VMAT was statistically lower than that of DCAT. The CI produced by DCAT plans for all patients was≥1, while the CI produced by VMAT plans did not achieve the ideal value of “1” for 17 patients. The HI produced by both VMAT and DCAT achieved a value < 2, with a p-value of 0.0479. The p-value of the irradiated volume or V25 (H10A) was < 0.0001, indicating that the null hypothesis, DCAT cannot produce a V25 ≤ to VMAT, failed to be rejected (Table 3).
      Table 3Average mean difference of all patient VMAT and DCAT plans, standard deviation, and p-value for CI, HI, and V25 of the treatment volume
      Critical metricsMean differenceStandard deviationp-value
      V20 of Lungs-0.06 %0.410.2622
      V15 of Liver-61.73 cc42.66< 0.0001
      p-value is statistically significant
      CI-0.180.06< 0.0001
      p-value is statistically significant
      HI0.060.130.0479
      p-value is statistically significant
      V25 of treatment volume-46.30 cc31.09< 0.0001
      p-value is statistically significant
      VMAT, Volumetric modulated arc therapy; DCAT, Dynamic conformal arc therapy; V20, volume receiving 20 Gray; V15, volume receiving 15 Gray; CI, conformity index; HI, homogeneity index; V25, total volume receiving 25 Gray; cc, cubic centimeters.
      low asterisk p-value is statistically significant

      Discussion

      Organs at risk

      The data from this study indicated that DCAT is effective in producing a mean dose to the kidneys (H2A), small bowel (H4A), and esophagus (H6A) statistically equivalent to that of VMAT, but is not effective in producing the same effect with the heart, large bowel, and stomach. It is important to note that statistical difference does not always imply clinical significance, especially if the mean dose produced overall is low compared to the recommended guidelines and constraints. Although VMAT was superior in reducing average doses to the heart, large bowel, and stomach, both DCAT and VMAT produced acceptable mean doses to these structures. The highest mean dose produced by DCAT was 555.6 cGy, 550.1 cGy, and 898.5 cGy to the heart, large bowel, and stomach, respectively. The highest mean dose produced by VMAT was 500.2 cGy, 518.2 cGy, and 803.5 cGy to the heart, large bowel, and stomach, respectively. The p-values were also just low enough to indicate statistical difference, indicating that statistical difference was not substantial. According to Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC) guidelines, the mean dose to the heart should not exceed 2600 cGy, and the maximum dose to the stomach should not exceed 4500 cGy.
      • Bentzen SM
      • Constine LS
      • Deasy JO
      • et al.
      Quantitative analyses of normal tissue effects in the clinic (QUANTEC): an introduction to the scientific issues.
      For 5 fraction SBRT treatments, it is also recommended that the maximum dose to the colon and stomach should not exceed 3800 cGy and 3200 cGy, respectively.
      • Bentzen SM
      • Constine LS
      • Deasy JO
      • et al.
      Quantitative analyses of normal tissue effects in the clinic (QUANTEC): an introduction to the scientific issues.
      Since DCAT nor VMAT exceeded values and had a very low overall average dose to these structures, it is unlikely that patients receiving SBRT to the liver with either method would experience side effects such as pericarditis, ulceration of the bowels or stomach. Since the mean dose to these structures was minimal, there is no evidence that the relative statistical difference of the two plans would make a clinical difference.
      For more radiosensitive structures such as the lung and the normal liver, it is critical to reduce dose to these structures to avoid RILD and radiation-induced pneumonitis.

      Mobius Medical Systems, 3D Dose Volume Histogram poster

      The V20 of the lungs was minimal (< 7.1% for VMAT, < 7.6% for DCAT) and was statistically equivalent between the two methods, proving that DCAT technique was effective in producing a statistically equivalent dose to the V20 of the lungs when compared to VMAT (H7A). However, the volume of the normal liver receiving 15 Gy proved to be a concerning metric, as DCAT was not able to produce optimal results compared to VMAT. Volumetric modulated arc therapy was able to produce V15 of the liver less than 700 cc for 18 patients, while the medical dosimetrist struggled with 2 patients and 1 additional patient for DCAT. The statistical analyses also concluded that VMAT was significantly superior in reducing V15 of the liver. In most SBRT cases concerning the liver, this critical metric assumes that a fractionated 15 Gy will produce a lower biologically equivalent dose, and that 500 cc are the minimum volume of normal liver required post resection for sufficient functioning of the organ. The V15 of the liver being < 700 cc is a widely accepted factor that has been documented to limit hepatic injury such as RILD, and a predictor for patient recovery from radiation induced toxicity to the liver within the first 3 months post radiation.
      • Koay EJ
      • Owen D
      • Das P.
      Radiation-induced liver disease and modern radiotherapy.
      Based on the foundations of this established metric; it can be concluded that the statistical significance between VMAT and DCAT for V15 of the liver is also clinically relevant - VMAT is superior and produces improved clinically acceptable plans compared to that of DCAT (Fig. 1). Due to the nature the nature dynamic arcs and its aperature conforming around a margin of the PTV without modulation of dose, this may contribute to increased scatter within the field and thus increased V15 to the liver. Previous researchers did not evaluate the V15 of the normal liver; however, the V30, V20, and V10 were also significantly higher in DCAT compared to those of VMAT.
      • Moon YM
      • Jeon W
      • Yu T
      • et al.
      Which is better for liver SBRT: dosimetric comparison between DCAT and VMAT for liver tumors.
      Fig 1
      Fig. 1Dose volume histogram comparison for the V15 liver metric for VMAT and DCAT plan for patient 16.

      Conformity, homogeneity, and irradiated volume

      Based on the results, DCAT achieved a better CI and HI than the VMAT plans, while VMAT was able to achieve a lower V25 compared to DCAT. The ideal value for CI is 1, and a CI ≥ 1 indicated that DCAT had better overall coverage of the PTV. The miniscule p-value (< 0.0001,) indicates strong statistical evidence that DCAT was superior in achieving a CI greater than or equal to 1 (H9A). A CI of < 1 was achieved for 18 patients planned with VMAT. This decreased PTV coverage in the VMAT plans could be due to several factors, including the interplay of MLCs during modulation to minimize average doses to OAR. There is increased internal organ motion due to the proximity of the liver to the diaphragm, requiring more stringent immobilization and/or QA to decrease the chance of geometric miss and deliver accurate dosage. The HI helps to measure the overall safety of SBRT plans and ensures that the plan is not excessively over-dosed. The acceptable range for this metric varies depending on treatment site and desired coverage. In general, SBRT plans are known to be less homogeneous within the PTV due to its ablative nature and tightening of the prescription line with minimal to no margin in order to prioritize conformity of dose to the target and minimize dose to OAR.
      • Macià I Garau M.
      Radiobiology of stereotactic body radiation therapy (SBRT).
      An HI < 2 ensures that the plan is not excessively high in dose. Although both DCAT and VMAT plans were able to achieve HI < 2, the p-value indicated enough statistical evidence to infer that DCAT was superior in producing a lower HI value.
      The V25 of the PTV volume helps to measure the difference of conformality of the prescription dose based on the PTV volume.
      • Bezjak A
      • Paulus R
      • Gaspar LE
      • et al.
      Safety and efficacy of a five-fraction stereotactic body radiotherapy schedule for centrally located non-small-cell lung cancer: NRG oncology/RTOG 0813 trial.
      The data provided robust evidence of statistical difference between VMAT and DCAT for this outcome with P < 0.0001; VMAT was superior to DCAT in producing a smaller irradiated volume. The metrics CI, HI, and V25 are correlated, and changing one can affect the other parameters. The VMAT plans had a lower V25 or the irradiated volume, resulting in a tighter 50% IDL. Consequentially, this produces increased hot spots and therefore a higher HI while lowering the CI for the VMAT plans (Figs. 2 and 3). Since the CI, HI, and V25 are correlated because one can affect the other, it may be up to the discretion of the physician to decide if the irradiated volume takes priority over coverage and/or homogeneity of dose to minimize dose to the OAR. Pokhrel et al.
      • Pokhrel D
      • Visak J
      • Sanford L.
      A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT.
      compared DCAT vs VMAT for SBRT of lung tumors and demonstrated that simple DCAT-based plans were able to improve target coverage with acceptable dose to OAR. However, the lack of density of the lung may contribute to the key difference in the ability of the DCAT plan to maintain a tighter intermediate dose spillage (V50%) in the lung, whereas tissue density in the abdominal region led to slightly increased intermediate dose spillage with DCAT in this study. This is further supported in the Moon et al.
      • Moon YM
      • Jeon W
      • Yu T
      • et al.
      Which is better for liver SBRT: dosimetric comparison between DCAT and VMAT for liver tumors.
      study, where DCAT for the liver produced higher CI but also consequently a higher D50%. There is an agreement of the CI and its effect on intermediate dose spillage with the use of DCAT between both studies. The improvement of the CI and HI of the DCAT plans, and consequently the expansion of the lower doses resulting in increased irradiated volume in the DCAT plans may also be a contributing factor for the slight increase of mean dose to the heart, large bowel, and stomach. The V15 of the liver may have been one of the organs affected by the V25 or intermediate dose spillage.
      Fig 2
      Fig. 2Isodose distribution showing the conformality around the PTV at isocenter for patient 19. (A) shows the DCAT plan and (B) shows the VMAT plan.
      Fig 3
      Fig. 3Homogeneity index and maximum dose for (A) showing the DCAT plan and (B) showing the VMAT plan.

      Conclusions

      The research problem was the paucity of literature comparing 3D DCAT to VMAT for early-stage or small metastatic liver lesions. The purpose of this retrospective study was to determine if the conformity of dose, irradiated volume, and dose to OAR are equivalent or improved with the use of 3D DCAT as an alternative method of treatment when compared to standard VMAT for SBRT treatment of liver lesions. While modulation with VMAT did show advantages in sparing some critical structures such as the heart, large bowel, and stomach, there was not a large degree of statistical significance in this study, and clinical significance is questionable. Dynamic conformal arc therapy was superior in producing CI > 1 and HI < 2 when compared to VMAT, but the increase in total irradiated volume due to a generally increased scatter was a consequential effect that may be linked to the increased dose in the heart, large bowel, stomach, and the liver. The V15 of the liver was the most concerning metric, as it determines the deliverability and safety of the plan. In this study, the V15 of the liver was greatly improved using VMAT when compared to DCAT. Based on this evaluation, it was concluded that VMAT was superior to DCAT for this study. Forward planned DCAT should not be considered as an alternative method for treating small lesions of the liver due to an increased V15, which compromises the safety of the treatment.
      The limitations of this study included the data collected at a single institution with a small sample size of 20 patients. Incorporating multiple institutions and a higher number of patients would improve the external validity and robustness of statistics within this study. Especially for certain metrics, such as V15 of the liver, the superiority between the 2 plans was determined by a difference of 1 patient. By creating a multi-institutional study, a larger number of patients with the same size tumor and location in the liver would help reduce the effect of confounding factors during the statistical analyses. Confounding factors can include different algorithms used in certain TPS, which may or may not affect the result of these plans. This study used Eclipse TPS with forward planned DCAT, whereas different TPS may include SSO and optimization for certain parameters to better avoid normal tissue. The patients in this study were limited to a diagnosis of early-stage or metastatic liver lesions within 2.0 to 5.0 cm. Future studies should include the evaluation of different size ranges or locations to stratify which patients may significantly benefit from VMAT. In addition, it may also be beneficial to evaluate the gradient index to further determine if DCAT is superior or equivalent to VMAT. Since this study concludes that doses to certain structures were statistically distinguished due to the p-value but may not be clinically significant, future studies may be needed to evaluate the clinical impact.

      Conflict of Interest

      The author declares no conflicts of interest.

      Acknowledgments

      The authors would like to thank Dr. David Reineke and the Statistical Consulting Center at the University of Wisconsin – La Crosse for assistance with the quantitative statistical analysis; however, any errors of fact or interpretation remain the sole responsibility of the authors.

      References

        • Siegel RL
        • Miller KD
        • Jemal A.
        Cancer statistics, 2020.
        CA Cancer J Clin. 2020; 70: 7-30https://doi.org/10.3322/caac.21590
        • Han L
        • Sintay B
        • Pearman K
        • et al.
        A hybrid planning strategy for stereotactic body radiation therapy of early stage non-small-cell lung cancer.
        J Appl Clin Med Phys. 2018; 19: 117-123https://doi.org/10.1002/acm2.12450
        • Afrin KT
        • Ahmad S.
        Is IMRT or VMAT superior or inferior to 3D conformal therapy in the treatment of lung cancer? A brief literature review.
        J Radiother Pract. 2021; : 1-5https://doi.org/10.1017/S146039692100008X
        • Bae SH
        • Jang WI
        • Park HC.
        Intensity-modulated radiotherapy for hepatocellular carcinoma: dosimetric and clinical results.
        Oncotarget. 2017; 8: 59965-59976https://doi.org/10.18632/oncotarget.19219
        • Tsai YL
        • Wu CJ
        • Shaw S
        • Yu PC
        • Nien HH
        • Lui LT.
        Quantitative analysis of respiration-induced motion of each liver segment with helical computed tomography and 4-dimensional computed tomography.
        Radiat Oncol. 2018; 13https://doi.org/10.1186/s13014-018-1007-0
        • Lu L
        • Diaconu C
        • Djemil T
        • et al.
        Intra- and inter-fractional liver and lung tumor motions treated with SBRT under active breathing control.
        J Appl Clin Med Phys. 2018; 19: 39-45https://doi.org/10.1002/acm2.12220
        • Edvardsson A
        • Nordstrom F
        • Ceberg C
        • Ceberg S.
        Motion induced interplay effects for VMAT radiotherapy.
        Phys Med Biol. 2018; 63https://doi.org/10.1088/1361-6560/aab957
        • Pokhrel D
        • Visak J
        • Sanford L.
        A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT.
        J Appl Clin Med Phys. 2020; 21: 29-38https://doi.org/10.1002/acm2.12878
        • Bokrantz R
        • Wedenberg M
        • Sandwall P.
        Dynamic conformal arcs for lung stereotactic body radiation therapy: a comparison with volumetric-modulated arc therapy.
        J Appl Clin Med Phys. 2020; 21: 103-109https://doi.org/10.1002/acm2.12800
        • Verma V
        • Ludmir EB
        • Mesko SM
        • et al.
        Commercial insurance coverage of advanced radiation therapy techniques compared with American society for radiation oncology model policies.
        Pract Radiat Oncol. 2020; 10: 324-329https://doi.org/10.1016/j.prro.2019.08.005
        • Roach MC
        • TO Thomas
        • Paravati AJ
        • Mahajan A.
        Differences in United States insurance payer policies and American society for radiation oncology's (ASTRO) model policy on stereotactic body radiation therapy (SBRT).
        Int J Radiat Oncol Biol Phys. 2019; 104: 740-744https://doi.org/10.1016/j.ijrobp.2019.01.005
        • Moon YM
        • Jeon W
        • Yu T
        • et al.
        Which is better for liver SBRT: dosimetric comparison between DCAT and VMAT for liver tumors.
        Front Oncol. 2020; 10https://doi.org/10.3389/fonc.2020.01170
        • Thaper D
        • Kamal R
        • Singh G
        • et al.
        Dosimetric comparison of dynamic conformal arc integrated with segment shape optimization and variable dose rate versus volumetric modulated arc therapy for liver SBRT.
        Rep Pract Oncol Radiother. 2020; 25: 667-677https://doi.org/10.1016/j.rpor.2020.04.017
        • Piana R.
        Rising costs in radiation oncology linked to medicare coverage.
        The ASCO Post. 2020; (Accessed from:) (Accessed at: April 1, 2021)
        • Dawson L.
        Randomized phase III study of sorafenib versus stereotactic body radiation therapy followed by sorafenib in hepatocellular carcinoma.
        Radiation Therapy Oncology Group (RTOG). 2021; (Accessed from:) (Accessed at: July 18, 2021)
        • Stanley J
        • Breitman K
        • Dunscombe P
        • Spencer DP
        • Lau H.
        Evaluation of stereotactic radiosurgery conformity indices for 170 target volumes in patients with brain metastases.
        J Appl Clin Med Phys. 2011; (Accessed from:) (Accessed at: February 20, 2022)
        • Bentzen SM
        • Constine LS
        • Deasy JO
        • et al.
        Quantitative analyses of normal tissue effects in the clinic (QUANTEC): an introduction to the scientific issues.
        Int J Radiat Oncol Biol Phys. 2010; 76: S3-S9https://doi.org/10.1016/j.ijrobp.2009.09.040
      1. Mobius Medical Systems, 3D Dose Volume Histogram poster

        • Koay EJ
        • Owen D
        • Das P.
        Radiation-induced liver disease and modern radiotherapy.
        Semin Radiat Oncol. 2018; 28: 321-331https://doi.org/10.1016/j.semradonc.2018.06.007
        • Macià I Garau M.
        Radiobiology of stereotactic body radiation therapy (SBRT).
        Rep Pract Oncol Radiother. 2017; 22: 86-95https://doi.org/10.1016/j.rpor.2017.02.010
        • Bezjak A
        • Paulus R
        • Gaspar LE
        • et al.
        Safety and efficacy of a five-fraction stereotactic body radiotherapy schedule for centrally located non-small-cell lung cancer: NRG oncology/RTOG 0813 trial.
        J Clin Oncol. 2019; 37: 1316-1325https://doi.org/10.1200/JCO.18.00622